Literature DB >> 12706011

Variability and repeatability of the flexion axis at the ulnohumeral joint.

Teresa R Duck1, Cynthia E Dunning, Graham J W King, James A Johnson.   

Abstract

Previous investigations have implemented screw displacement axes (SDAs) to define the elbow flexion axis for proper positioning of dynamic external fixators and endoprostheses. However, results across studies vary, which may be attributed to forearm position (pronation-supination) during elbow motion, or the mode of loading (active/passive) employed to generate flexion. Therefore, the aim of this study was to determine the influence of the flexion mode employed and forearm position on individual variation and repeatability of SDAs throughout elbow flexion. With the forearm pronated, the location of the average SDA was similar whether elbow flexion was generated actively or passively. In contrast, with the forearm supinated, the average SDA was 2.4 degrees and 1.4 degrees more valgus (p<0.001) and internally rotated (p<0.001), respectively, and positioned 1.6 and 0.8 mm further proximally (p=0.002) and anteriorly (p=0.005) relative to the capitellum, respectively, during active compared to passive flexion. During active flexion, the location of the average SDA was independent of forearm position. Conversely, during passive flexion, the average SDA angle was 3.4 degrees and 1.0 degrees more valgus (p<0.001) and internally rotated (p=0.009), respectively, and 1.7 and 0.7 mm more proximal (p<0.001) and anterior (p=0.001) relative to the capitellum, respectively, with the forearm held pronated rather than supinated. SDAs calculated throughout flexion deviated from the average SDA in both orientation and position, demonstrating that elbow flexion behaves similar to a loose hinge joint. These factors suggest that to encompass the location of all SDAs throughout flexion, and therefore properly mimic normal elbow joint motion, an endoprosthesis should be modeled similar to a "loose" rather than "pure" hinge joint. This would allow for dependencies of SDA angulation on forearm position and muscle activation, and slight freedom of movement to account for variances in SDA location. These factors should also be considered during soft-tissue reconstructions.

Entities:  

Mesh:

Year:  2003        PMID: 12706011     DOI: 10.1016/S0736-0266(02)00198-5

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  7 in total

1.  Experimental determination of the elbow's center of rotation using the VICON™ optoelectronic motion capture system.

Authors:  Elvire Guerre; Pascale Laronde; Jérôme Cussonneau; Christian Fontaine; Guillaume Wavreille
Journal:  Surg Radiol Anat       Date:  2015-11-20       Impact factor: 1.246

2.  Vortical flow in human elbow joints: a three-dimensional computed tomography modeling study.

Authors:  Arnold Adikrishna; Aashay L Kekatpure; Jun Tan; Hyun-Joo Lee; Maria Florencia Deslivia; In-Ho Jeon
Journal:  J Anat       Date:  2014-08-05       Impact factor: 2.610

3.  Distal Humeral Trochlear Geometry Associated With the Spatial Variation of the Dynamic Elbow Flexion Axis.

Authors:  Diyang Zou; Xiangjun Hu; Kai-Nan An; Kerong Dai; Xiaowei Yu; Weihua Gong; Tsung-Yuan Tsai
Journal:  Front Bioeng Biotechnol       Date:  2022-06-24

4.  Does the triceps-on approach affect alignment in total elbow arthroplasty? A cadaveric study.

Authors:  Andrew King; Jonathan P Evans; Simon J Booker; James Cs Beazley; Robin Js Jones; William Jc Thomas; Christopher Smith
Journal:  Shoulder Elbow       Date:  2018-05-25

5.  The dynamic rotation axis of ulnohumeral joint during active flexion-extension: an in vivo 4-dimensional computed tomography analysis.

Authors:  Hua Liu; Erica Kholinne; Yucheng Sun; Tingting Liu; Jun Tan
Journal:  BMC Musculoskelet Disord       Date:  2022-02-16       Impact factor: 2.362

6.  Feasibility of four-dimensional preoperative simulation for elbow debridement arthroplasty.

Authors:  Michiro Yamamoto; Yukimi Murakami; Katsuyuki Iwatsuki; Shigeru Kurimoto; Hitoshi Hirata
Journal:  BMC Musculoskelet Disord       Date:  2016-04-02       Impact factor: 2.362

7.  Functional Classification of the Medial Ulnar Collateral Ligament: An In Vivo Kinematic Study With Computer-Aided Design.

Authors:  Erica Kholinne; Rizki Fajar Zulkarnain; Hyun-Joo Lee; Arnold Adikrishna; In-Ho Jeon
Journal:  Orthop J Sports Med       Date:  2018-03-23
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.