Normal and abnormal trans-oxygenator pressure gradients during cardiopulmonary bypass.

Anthony Richard Fisher1, Mya Baker, Mike Buffin, Patrick Campbell, Stephen Hansbro, Steven Kennington, Angela Lilley, Michael Whitehorne.   

Abstract

A prospective study was conducted with the aims of 1) determining the normal trans-oxygenator pressure gradient characteristics for a range of oxygenators and 2) determining the characteristics, incidence and outcome of abnormally raised gradients. The trans-oxygenator pressure gradient was monitored in 3684 patients undergoing open-heart surgery in eight different hospitals. When the normal pressure gradient was measured during cardiopulmonary bypass in mmHg/L blood flow, a constant figure was obtained which was specific for each oxygenator. This gradient was abnormally raised in 16 cases (one in every 230 cases) and was raised to such an extent in three of these cases that an emergency oxygenator changeout was required (one in every 1228 cases). Among the 16 reported incidents, three different patterns of gradient changes occurred, suggesting the possibility that there were three different aetiologies. In nine of these incidents, the pressure gradient was normal immediately upon going on bypass, but rose rapidly to a plateau value, which then returned to the normal value within 40 minutes. In three cases, the pressure gradient was raised immediately upon going on bypass and then rapidly returned to the baseline. In one case, the pressure gradient was raised immediately upon going on bypass and stayed raised throughout the operation.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12705647     DOI: 10.1191/0267659103pf635oa

Source DB:  PubMed          Journal:  Perfusion        ISSN: 0267-6591            Impact factor:   1.972


  3 in total

1.  Extracorporeal circulation technical training DVD volume 1: basic operation and troubleshooting scenarios.

Authors:  Yasuko Tomizawa; Naoki Momose; Toru Matayoshi
Journal:  J Artif Organs       Date:  2009-12-25       Impact factor: 1.731

2.  Survey: retrospective survey of monitoring/safety devices and incidents of cardiopulmonary bypass for cardiac surgery in France.

Authors:  Jean-Mathias Charrière; Jérôme Pélissié; Christophe Verd; Philippe Léger; Philippe Pouard; Charles de Riberolles; Pascal Menestret; Marie-Claude Hittinger; Dan Longrois
Journal:  J Extra Corpor Technol       Date:  2007-09

3.  Insights into Gradient and Anisotropic Pore Structures of Capiox® Gas Exchange Membranes for ECMO: Theoretically Verifying SARS-CoV-2 Permeability.

Authors:  Makoto Fukuda; Ryo Tanaka; Kazunori Sadano; Asako Tokumine; Tomohiro Mori; Hitoshi Saomoto; Kiyotaka Sakai
Journal:  Membranes (Basel)       Date:  2022-03-10
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.