Literature DB >> 12705342

National external quality assessment scheme for lymphocyte immunophenotyping in Belgium.

Marian Van Blerk1, Michel Bernier, Xavier Bossuyt, Bernard Chatelain, Jean-Luc D'Hautcourt, Christian Demanet, Luc Kestens, Dirk Van Bockstaele, Tania Crucitti, Jean-Claude Libeer.   

Abstract

In 2000, the Belgian Scientific Institute of Public Health introduced a voluntary external quality assessment scheme for lymphocyte immunophenotyping. This paper provides an analysis of the first six surveys. Specimens consisted of fresh EDTA-anticoagulated whole blood and were sent by overnight mail. The 41 participants were surveyed for methodology and were asked to report white blood cell count, percentage of lymphocytes, and percentages and absolute numbers of CD3+, CD4+, CD8+, and CD19+ cells. Median intralaboratory coefficients of variation were 1.0, 1.3, 1.7, and 3.2% for CD3+, CD4+, CD8+, and CD19+ cell percentages, respectively. Interlaboratory variability was consistently lower than 6.5% for CD3+ and CD4+CD3+ cell percentages, and lower than 9.5% for CD8+CD3+ cell percentages. Median coefficients of variation for the absolute values were higher, ranging from 10.1% for CD4+CD3+ cells to 16.5% for CD19+ cells. The percentage of CD4+CD3+ and CD8+ CD3+ cells was in several samples significantly lower than the percentage of total CD4+ and CD8+ cells. The number of laboratories measuring total CD4+ and CD8+ cells decreased by 30% during the programme. Between-laboratory variability remained stable over time. Analysis of individual laboratory performance indicated that some laboratories markedly improved their results.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12705342     DOI: 10.1515/CCLM.2003.052

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  3 in total

1.  Rapid cell population identification in flow cytometry data.

Authors:  Nima Aghaeepour; Radina Nikolic; Holger H Hoos; Ryan R Brinkman
Journal:  Cytometry A       Date:  2011-01       Impact factor: 4.355

Review 2.  A Critical Review on the Standardization and Quality Assessment of Nonfunctional Laboratory Tests Frequently Used to Identify Inborn Errors of Immunity.

Authors:  Sandro Félix Perazzio; Patricia Palmeira; Dewton Moraes-Vasconcelos; Andréia Rangel-Santos; João Bosco de Oliveira; Luis Eduardo Coelho Andrade; Magda Carneiro-Sampaio
Journal:  Front Immunol       Date:  2021-11-09       Impact factor: 7.561

3.  Merging mixture components for cell population identification in flow cytometry.

Authors:  Greg Finak; Ali Bashashati; Ryan Brinkman; Raphaël Gottardo
Journal:  Adv Bioinformatics       Date:  2009-11-12
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.