Literature DB >> 12705035

A laboratory investigation of the accuracy of the repositioning impression coping technique at the implant level for single-tooth implants.

M Firas Daoudi1, Derrick J Setchell, Lloyd J Searson.   

Abstract

This study investigated the accuracy of the repositioning impression technique at the implant level using vinyl polysiloxane impression material. Three groups each of ten senior dentists, postgraduate students and technicians were asked to use this technique to record the position of an implant in a master model. The Reflex Microscope was used to measure variations between the resulting casts and the master model. Significant difference between the casts and the master model in the X and Y-axes (p < 0.01) was recorded. Alarming inclinational and rotational errors for the implant analogue position were measured with all groups of operators. Similar distortion in the Z-axis was recorded.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12705035

Source DB:  PubMed          Journal:  Eur J Prosthodont Restor Dent        ISSN: 0965-7452


  2 in total

1.  Effect of different impression materials and techniques on the dimensional accuracy of implant definitive casts.

Authors:  Behnaz Ebadian; Mansor Rismanchian; Badrosadat Dastgheib; Farshad Bajoghli
Journal:  Dent Res J (Isfahan)       Date:  2015 Mar-Apr

2.  A comparative analysis of the accuracy of implant master casts fabricated from two different transfer impression techniques.

Authors:  Rupali Patil; Pankaj Kadam; Chetan Oswal; Seema Patil; Shweta Jajoo; Arati Gachake
Journal:  J Int Soc Prev Community Dent       Date:  2016 Mar-Apr
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.