Literature DB >> 12704778

Balanced phase-contrast steady-state free precession (PC-SSFP): a novel technique for velocity encoding by gradient inversion.

M Markl1, M T Alley, N J Pelc.   

Abstract

A technique for measuring velocity is presented that combines cine phase contrast (PC) MRI and balanced steady-state free precession (SSFP) imaging, and is thus termed PC-SSFP. Flow encoding was performed without the introduction of additional velocity encoding gradients in order to keep the repetition time (TR) as short as in typical SSFP imaging sequences. Sensitivity to through-plane velocities was instead established by inverting (i.e., negating) all gradients along the slice-select direction. Velocity sensitivity (VENC) could be adjusted by altering the first moments of the slice-select gradients. Disturbances of the SSFP steady state were avoided by acquiring different flow echoes in consecutively (i.e., sequentially) executed scans, each over several cardiac cycles, using separate steady-state preparation periods. A comparison of phantom measurements with those from established 2D-cine-PC MRI demonstrated excellent correlation between both modalities. In examinations of volunteers, PC-SSFP exhibited a higher intrinsic signal-to-noise ratio (SNR) and consequently low phase noise in measured velocities compared to conventional PC scans. An additional benefit of PC-SSFP is that it relies less on in-flow-dependent signal enhancement, and thus yields more uniform SNRs and better depictions of vessel geometry throughout the whole cardiac cycle in structures with slow and/or pulsatile flow. Copyright 2003 Wiley-Liss, Inc.

Mesh:

Substances:

Year:  2003        PMID: 12704778     DOI: 10.1002/mrm.10451

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  10 in total

1.  Pulse sequences for phase-contrast SSFP imaging from a single steady-state.

Authors:  J-F Nielsen; K S Nayak
Journal:  Proc Int Soc Magn Reson Med Sci Meet Exhib Int Soc Magn Reson Med Sci Meet Exhib       Date:  2006-05

2.  SSFP and GRE phase contrast imaging using a three-echo readout.

Authors:  Jon-Fredrik Nielsen; Krishna S Nayak
Journal:  Magn Reson Med       Date:  2007-12       Impact factor: 4.668

3.  Interleaved balanced SSFP imaging: artifact reduction using gradient waveform grouping.

Authors:  Jon-Fredrik Nielsen; Krishna S Nayak
Journal:  J Magn Reson Imaging       Date:  2009-03       Impact factor: 4.813

4.  Three-dimensional, isotropic MRI: a unified approach to quantification and visualization in congenital heart disease.

Authors:  Thomas Sangild Sørensen; Philipp Beerbaum; Hermann Körperich; Erik Morre Pedersen
Journal:  Int J Cardiovasc Imaging       Date:  2005 Apr-Jun       Impact factor: 2.357

5.  Virtual dye angiography: flow visualization for MRI-guided interventions.

Authors:  Ashvin K George; Anthony Z Faranesh; Kanishka Ratnayaka; J Andrew Derbyshire; Robert J Lederman; Michael S Hansen
Journal:  Magn Reson Med       Date:  2011-08-19       Impact factor: 4.668

6.  Accelerated phase-contrast cine MRI using k-t SPARSE-SENSE.

Authors:  Daniel Kim; Hadrien A Dyvorne; Ricardo Otazo; Li Feng; Daniel K Sodickson; Vivian S Lee
Journal:  Magn Reson Med       Date:  2011-11-14       Impact factor: 4.668

7.  Coronary artery flow measurement using navigator echo gated phase contrast magnetic resonance velocity mapping at 3.0 T.

Authors:  Kevin Johnson; Puneet Sharma; John Oshinski
Journal:  J Biomech       Date:  2007-11-26       Impact factor: 2.712

8.  Fetal whole-heart 4D imaging using motion-corrected multi-planar real-time MRI.

Authors:  Joshua F P van Amerom; David F A Lloyd; Maria Deprez; Anthony N Price; Shaihan J Malik; Kuberan Pushparajah; Milou P M van Poppel; Mary A Rutherford; Reza Razavi; Joseph V Hajnal
Journal:  Magn Reson Med       Date:  2019-05-12       Impact factor: 4.668

Review 9.  Quantification in cardiac MRI: advances in image acquisition and processing.

Authors:  Anil K Attili; Andreas Schuster; Eike Nagel; Johan H C Reiber; Rob J van der Geest
Journal:  Int J Cardiovasc Imaging       Date:  2010-02       Impact factor: 2.357

10.  Fetal whole heart blood flow imaging using 4D cine MRI.

Authors:  Thomas A Roberts; Joshua F P van Amerom; Alena Uus; David F A Lloyd; Milou P M van Poppel; Anthony N Price; Jacques-Donald Tournier; Chloe A Mohanadass; Laurence H Jackson; Shaihan J Malik; Kuberan Pushparajah; Mary A Rutherford; Reza Razavi; Maria Deprez; Joseph V Hajnal
Journal:  Nat Commun       Date:  2020-10-05       Impact factor: 14.919

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.