Literature DB >> 1270471

The permeability of articular cartilage under compressive strain and at high pressures.

J M Mansour, V C Mow.   

Abstract

The permeability of bovine articular cartilage was measured in an apparatus designed to permit this measurement while the fluid pressure gradient across the cartilage and the axial compressive strain applied to the cartilage were varied independently. For all of the pressure gradients tested the permeability of the cartilage decreased as the compressive strain increased. From previous work, it was postulated that joint lubrication is accomplished first by fluid exudation into the joint space. both at the leading edge of the moving contact area and between portions of the opposing cartilaginous surfaces, and second by imbibition of the expelled fluid back into the cartilage toward the trailing edge of the contact area caused by the "elastic" recovery of the tissue. The present work extends this model to include the condition that the permeability of cartilage is dependent on the extent to which it is deformed.

Entities:  

Mesh:

Year:  1976        PMID: 1270471

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  27 in total

1.  Tissue engineering science: consequences of cell traction force.

Authors:  R T Tranquillo; M A Durrani; A G Moon
Journal:  Cytotechnology       Date:  1992       Impact factor: 2.058

2.  Mechanical behavior of carpal tunnel subsynovial connective tissue under compression.

Authors:  Jessica E Goetz; Thomas E Baer
Journal:  Iowa Orthop J       Date:  2011

3.  Three-dimensional morphometry of strained bovine periodontal ligament using synchrotron radiation-based tomography.

Authors:  Marzio Bergomi; Joël Cugnoni; H W Anselm Wiskott; Philipp Schneider; Marco Stampanoni; John Botsis; Urs C Belser
Journal:  J Anat       Date:  2010-06-14       Impact factor: 2.610

4.  Finite element implementation of mechanochemical phenomena in neutral deformable porous media under finite deformation.

Authors:  Gerard A Ateshian; Michael B Albro; Steve Maas; Jeffrey A Weiss
Journal:  J Biomech Eng       Date:  2011-08       Impact factor: 2.097

5.  Biomimetic molecules lower catabolic expression and prevent chondroitin sulfate degradation in an osteoarthritic ex vivo model.

Authors:  Shaili Sharma; Nelda Vazquez-Portalatin; Sarah Calve; Alyssa Panitch
Journal:  ACS Biomater Sci Eng       Date:  2015-12-23

6.  Anisotropic hydraulic permeability under finite deformation.

Authors:  Gerard A Ateshian; Jeffrey A Weiss
Journal:  J Biomech Eng       Date:  2010-11       Impact factor: 2.097

7.  A theoretical analysis of water transport through chondrocytes.

Authors:  G A Ateshian; K D Costa; C T Hung
Journal:  Biomech Model Mechanobiol       Date:  2006-05-17

8.  Anisotropy, inhomogeneity, and tension-compression nonlinearity of human glenohumeral cartilage in finite deformation.

Authors:  Chun-Yuh Huang; Anna Stankiewicz; Gerard A Ateshian; Van C Mow
Journal:  J Biomech       Date:  2005-04       Impact factor: 2.712

9.  Permeability of canine vocal fold lamina propria.

Authors:  Jacob P Meyer; Anton A Kvit; Erin E Devine; Jack Jiang
Journal:  Laryngoscope       Date:  2014-12-10       Impact factor: 3.325

10.  Influence of pore size on tensile strength, permeability and porosity of hyaluronan-collagen scaffolds.

Authors:  Amir A Al-Munajjed; Matthias Hien; Richard Kujat; John P Gleeson; Joachim Hammer
Journal:  J Mater Sci Mater Med       Date:  2008-03-18       Impact factor: 3.896

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.