Literature DB >> 12701892

Washout studies of 11C in rabbit thigh muscle implanted by secondary beams of HIMAC.

T Tomitani1, J Pawelke, M Kanazawa, K Yoshikawa, K Yoshida, M Sato, A Takami, M Koga, Y Futami, A Kitagawa, E Urakabe, M Suda, H Mizuno, T Kanai, H Matsuura, I Shinoda, S Takizawa.   

Abstract

Heavy ion therapy has two definite advantages: good dose localization and higher biological effect. Range calculation of the heavy ions is an important factor in treatment planning. X-ray CT numbers are used to estimate the heavy ion range by looking up values in a conversion table which relates empirically photon attenuation in tissues to particle stopping power; this is one source of uncertainty in the treatment planning. Use of positron emitting radioactive beams along with a positron emission tomograph or a positron camera gives range information and may be used as a means of checking in heavy ion treatment planning. However, the metabolism of the implanted positron emitters in a living object is unpredictable because the chemical forms of these emitters are unknown and the metabolism is dependent on the organ species and may be influenced by many factors such as blood flow rate and fluid components present. In this paper, the washout rate of 11C activity implanted by injecting energetic 11C beams into thigh muscle of a rear leg of a rabbit is presented. The washout was found to consist of two components, the shorter one was about 4.2 +/- 1.1 min and the longer one ranged from 91 to 124 min. About one third of the implanted beta+ activity can be used for imaging and the rest was washed out of the target area.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12701892     DOI: 10.1088/0031-9155/48/7/305

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  13 in total

1.  System design of a small OpenPET prototype with 4-layer DOI detectors.

Authors:  Eiji Yoshida; Shoko Kinouchi; Hideaki Tashima; Fumihiko Nishikido; Naoko Inadama; Hideo Murayama; Taiga Yamaya
Journal:  Radiol Phys Technol       Date:  2011-11-29

2.  Imaging simulations of an "OpenPET" geometry with shifting detector rings.

Authors:  Taiga Yamaya; Taku Inaniwa; Shinichiro Mori; Takuji Furukawa; Shinichi Minohara; Eiji Yoshida; Fumihiko Nishikido; Kengo Shibuya; Naoko Inadama; Hideo Murayama
Journal:  Radiol Phys Technol       Date:  2008-12-09

3.  Feasibility study of using fall-off gradients of early and late PET scans for proton range verification.

Authors:  Jongmin Cho; Kira Grogg; Chul Hee Min; Xuping Zhu; Harald Paganetti; Hyun Cheol Lee; Georges El Fakhri
Journal:  Med Phys       Date:  2017-03-30       Impact factor: 4.071

Review 4.  The promise and pitfalls of positron emission tomography and single-photon emission computed tomography molecular imaging-guided radiation therapy.

Authors:  Richard L Wahl; Joseph M Herman; Eric Ford
Journal:  Semin Radiat Oncol       Date:  2011-04       Impact factor: 5.934

5.  Proton therapy dosimetry using positron emission tomography.

Authors:  Matthew T Studenski; Ying Xiao
Journal:  World J Radiol       Date:  2010-04-28

6.  PET/CT imaging for treatment verification after proton therapy: a study with plastic phantoms and metallic implants.

Authors:  Katia Parodi; Harald Paganetti; Ethan Cascio; Jacob B Flanz; Ali A Bonab; Nathaniel M Alpert; Kevin Lohmann; Thomas Bortfeld
Journal:  Med Phys       Date:  2007-02       Impact factor: 4.071

7.  Experimental verification of proton beam monitoring in a human body by use of activity image of positron-emitting nuclei generated by nuclear fragmentation reaction.

Authors:  Teiji Nishio; Aya Miyatake; Kazumasa Inoue; Tomoko Gomi-Miyagishi; Ryosuke Kohno; Satoru Kameoka; Keiichi Nakagawa; Takashi Ogino
Journal:  Radiol Phys Technol       Date:  2007-11-27

8.  Determination of elemental tissue composition following proton treatment using positron emission tomography.

Authors:  Jongmin Cho; Geoffrey Ibbott; Michael Gillin; Carlos Gonzalez-Lepera; Chul Hee Min; Xuping Zhu; Georges El Fakhri; Harald Paganetti; Osama Mawlawi
Journal:  Phys Med Biol       Date:  2013-05-16       Impact factor: 3.609

9.  Patient study of in vivo verification of beam delivery and range, using positron emission tomography and computed tomography imaging after proton therapy.

Authors:  Katia Parodi; Harald Paganetti; Helen A Shih; Susan Michaud; Jay S Loeffler; Thomas F DeLaney; Norbert J Liebsch; John E Munzenrider; Alan J Fischman; Antje Knopf; Thomas Bortfeld
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-07-01       Impact factor: 7.038

10.  Dynamic PET/CT measurements of induced positron activity in a prostate cancer patient after 50-MV photon radiation therapy.

Authors:  Sara Janek Strååt; Hans Jacobsson; Marilyn E Noz; Björn Andreassen; Ingemar Näslund; Cathrine Jonsson
Journal:  EJNMMI Res       Date:  2013-01-23       Impact factor: 3.138

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.