Elizaveta A Kasparova1, Arcady A Kasparov. 1. New Line Vision Ophthalmology Research Center, State Research Institute of Eye Diseases RAMN, Moscow Russia. cornea@orc.ru
Abstract
PURPOSE: To report our results using PRK combined with PTK to treat keratoconus. METHODS: Forty-one patients (70 eyes) underwent PRK+PTK with a Nidek EC-5000 excimer laser. PRK included spherical or cylindrical ablations, or both. PRK ablation zone diameter was 6.00 mm. PTK was performed with an ablation zone diameter of 8.00 mm and a transition zone of 9 mm. PTK ablation zone was decentered toward the cone apex, according to corneal topography. RESULTS: Refractive results: UCVA increased from 0.07 +/- 0.003 to 0.76 +/- 0.03 (69.2% of eyes had uncorrected visual acuity of 1.0); mean BSCVA increased from 0.70 +/- 0.03 to 0.83 +/- 0.04; myopia decreased from a mean 5.32 +/- 0.62 D to 1.55 +/- 0.30 D and astigmatism decreased from a mean 3.25 +/- 0.53 D to 1.75 +/- 0.25 D. Therapeutic results: Keratoconus progression was stopped in 91.43% of eyes with a mean follow-up of 3.5 years and maximum follow-up of 6 years. CONCLUSION: PRK+PTK with the Nidek EC-5000 excimer laser was an excellent option for patients with primary keratoconus.
PURPOSE: To report our results using PRK combined with PTK to treat keratoconus. METHODS: Forty-one patients (70 eyes) underwent PRK+PTK with a Nidek EC-5000 excimer laser. PRK included spherical or cylindrical ablations, or both. PRK ablation zone diameter was 6.00 mm. PTK was performed with an ablation zone diameter of 8.00 mm and a transition zone of 9 mm. PTK ablation zone was decentered toward the cone apex, according to corneal topography. RESULTS: Refractive results: UCVA increased from 0.07 +/- 0.003 to 0.76 +/- 0.03 (69.2% of eyes had uncorrected visual acuity of 1.0); mean BSCVA increased from 0.70 +/- 0.03 to 0.83 +/- 0.04; myopia decreased from a mean 5.32 +/- 0.62 D to 1.55 +/- 0.30 D and astigmatism decreased from a mean 3.25 +/- 0.53 D to 1.75 +/- 0.25 D. Therapeutic results: Keratoconus progression was stopped in 91.43% of eyes with a mean follow-up of 3.5 years and maximum follow-up of 6 years. CONCLUSION: PRK+PTK with the Nidek EC-5000 excimer laser was an excellent option for patients with primary keratoconus.
Authors: L Fernández-Vega-Cueto; V Romano; R Zaldivar; C H Gordillo; F Aiello; D Madrid-Costa; J F Alfonso Journal: J Ophthalmol Date: 2017-12-18 Impact factor: 1.909
Authors: Efstratios A Parikakis; Irini P Chatziralli; Vasileios G Peponis; Georgios David; Spyridon Chalkiadakis; Panagiotis G Mitropoulos Journal: Case Rep Ophthalmol Date: 2013-11-02
Authors: Gabriel de Almeida Ferreira; Vinícius Coral Ghanem; Renata Leite de Pinho Tavares; Ramon Coral Ghanem Journal: Indian J Ophthalmol Date: 2020-11 Impact factor: 1.848