Tissue temperature-controlled radiofrequency ablation.

Olaf J Eick1, Dirk Bierbaum.   

Abstract

During radiofrequency energy delivery, the catheter tip temperature can be significantly lower than the tissue temperature. The authors performed tissue temperature-controlled radiofrequency ablation in vitro and evaluated the effects of cooling, electrode to tissue contact, and target tissue temperature on lesion size. Pieces of porcine ventricle were immersed in a bath of isotonic saline solution at 37 degrees C. Radiofrequency energy was controlled by the tissue temperature as measured with a thermocouple needle placed 2 mm beneath the ablation electrode. Radiofrequency power was delivered for 30 seconds and limited to 50 W. A total of 81 radiofrequency ablations was performed with different electrode to tissue contact forces (0.04 N, 0.36 N, and 0.67 N) and target tissue temperatures (50 degrees C, 60 degrees C, and 70 degrees C) using an irrigated (27 ablations, 20 mL/min irrigation flow rate) or a nonirrigated ablation catheter. Twenty-seven nonirrigated applications were performed with fluid flow maintained by the pump of the thermostat and another 27 applications without flow. Every combination was applied three times and the average values were used for evaluation. For tissue target temperatures of 50 degrees C, 60 degrees C, and 70 degrees C, the lesion volume for nonirrigated ablations was on average 21 +/- 8 mm3, 45 +/- 23 mm3, and 109 +/- 45 mm3, respectively, and for irrigated ablations 12 +/- 7 mm3, 37 +/- 20 mm3, and 92 +/- 30 mm3, respectively. In both application groups the lesion size did not correlate with the electrode to tissue contact force. In the nonirrigated ablation group there was no difference in lesion size between the group with fluid flow and those without. Lesion size during tissue temperature-controlled radiofrequency delivery increases with increasing target tissue temperature and becomes independent of flow and electrode to tissue contact.

Entities:  

Mesh:

Year:  2003        PMID: 12698673     DOI: 10.1046/j.1460-9592.2003.00123.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  9 in total

1.  Can noncontact mapping distinguish between endo- and epicardial foci?

Authors:  Frederik Voss; Alexander Bauer; Steffen Witte; Hugo A Katus; Ruediger Becker
Journal:  Clin Res Cardiol       Date:  2008-05-03       Impact factor: 5.460

2.  Thermal strain imaging: a review.

Authors:  Chi Hyung Seo; Yan Shi; Sheng-Wen Huang; Kang Kim; Matthew O'Donnell
Journal:  Interface Focus       Date:  2011-05-23       Impact factor: 3.906

3.  Using temperature-time integration as a critical parameter in using monopolar radiofrequency ablations.

Authors:  Yen-Liang Chang; Te-Ming Tseng; Po-Yueh Chen; Chun-Ju Lin; Shih-Han Hung
Journal:  Eur Arch Otorhinolaryngol       Date:  2014-02-06       Impact factor: 2.503

4.  The feasibility of using thermal strain imaging to regulate energy delivery during intracardiac radio-frequency ablation.

Authors:  Chi Hyung Seo; Douglas N Stephens; Jonathan Cannata; Aaron Dentinger; Feng Lin; Suhyun Park; Douglas Wildes; Kai E Thomenius; Peter Chen; Tho Nguyen; Alan de La Rama; Jong Seob Jeong; Aman Mahajan; Kalyanam Shivkumar; Amin Nikoozadeh; Omer Oralkan; Uyen Truong; David J Sahn; Pierre T Khuri-Yakub; Matthew O'Donnell
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-07       Impact factor: 2.725

5.  Direct cooling of the catheter tip increases safety for CMR-guided electrophysiological procedures.

Authors:  Theresa Reiter; Daniel Gensler; Oliver Ritter; Ingo Weiss; Wolfgang Geistert; Ralf Kaufmann; Sabine Hoffmeister; Michael T Friedrich; Stefan Wintzheimer; Markus Düring; Peter Nordbeck; Peter M Jakob; Mark E Ladd; Harald H Quick; Wolfgang R Bauer
Journal:  J Cardiovasc Magn Reson       Date:  2012-02-01       Impact factor: 5.364

6.  Temperature controlled radiofrequency ablation.

Authors:  Olaf J Eick
Journal:  Indian Pacing Electrophysiol J       Date:  2002-07-01

7.  The symbiosis of contact force catheter use for hybrid ablation for atrial fibrillation.

Authors:  N Kumar; L Pison; P Lozekoot; R Choudhury; M La Meir; S Gelsomino; H Crijns; J Maessen
Journal:  Neth Heart J       Date:  2015-08       Impact factor: 2.380

8.  Free Tools and Strategies for the Generation of 3D Finite Element Meshes: Modeling of the Cardiac Structures.

Authors:  E Pavarino; L A Neves; J M Machado; M F de Godoy; Y Shiyou; J C Momente; G F D Zafalon; A R Pinto; C R Valêncio
Journal:  Int J Biomed Imaging       Date:  2013-05-16

9.  Fiber Bragg Grating Sensors for Millimetric-Scale Temperature Monitoring of Cardiac Tissue Undergoing Radiofrequency Ablation: A Feasibility Assessment.

Authors:  Martina Zaltieri; Greta Allegretti; Carlo Massaroni; Emiliano Schena; Filippo Maria Cauti
Journal:  Sensors (Basel)       Date:  2020-11-13       Impact factor: 3.576

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.