Literature DB >> 12696798

Global convergence analysis of fast multiobjective gradient-based dose optimization algorithms for high-dose-rate brachytherapy.

M Lahanas1, D Baltas, S Giannouli.   

Abstract

We consider the problem of the global convergence of gradient-based optimization algorithms for interstitial high-dose-rate (HDR) brachytherapy dose optimization using variance-based objectives. Possible local minima could lead to only sub-optimal solutions. We perform a configuration space analysis using a representative set of the entire non-dominated solution space. A set of three prostate implants is used in this study. We compare the results obtained by conjugate gradient algorithms, two variable metric algorithms and fast-simulated annealing. For the variable metric algorithm BFGS from numerical recipes, large fluctuations are observed. The limited memory L-BFGS algorithm and the conjugate gradient algorithm FRPR are globally convergent. Local minima or degenerate states are not observed. We study the possibility of obtaining a representative set of non-dominated solutions using optimal solution rearrangement and a warm start mechanism. For the surface and volume dose variance and their derivatives, a method is proposed which significantly reduces the number of required operations. The optimization time, ignoring a preprocessing step, is independent of the number of sampling points in the planning target volume. Multiobjective dose optimization in HDR brachytherapy using L-BFGS and a new modified computation method for the objectives and derivatives has been accelerated, depending on the number of sampling points, by a factor in the range 10-100.

Mesh:

Year:  2003        PMID: 12696798     DOI: 10.1088/0031-9155/48/5/304

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  Optimization of light sources for prostate photodynamic therapy.

Authors:  Martin D Altschuler; Timothy C Zhu; Jun Li; Stephen M Hahn
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2005-04-22

2.  Optimized interstitial PDT prostate treatment planning with the Cimmino feasibility algorithm.

Authors:  Martin D Altschuler; Timothy C Zhu; Jun Li; Stephen M Hahn
Journal:  Med Phys       Date:  2005-12       Impact factor: 4.071

3.  Radiobiological evaluation of the influence of dwell time modulation restriction in HIPO optimized HDR prostate brachytherapy implants.

Authors:  Panayiotis Mavroidis; Zaira Katsilieri; Vasiliki Kefala; Natasa Milickovic; Nikos Papanikolaou; Andreas Karabis; Nikolaos Zamboglou; Dimos Baltas
Journal:  J Contemp Brachytherapy       Date:  2010-10-13

4.  Comparison of IPSA and HIPO inverse planning optimization algorithms for prostate HDR brachytherapy.

Authors:  Vanessa Panettieri; Ryan L Smith; Natasha J Mason; Jeremy L Millar
Journal:  J Appl Clin Med Phys       Date:  2014-11-08       Impact factor: 2.102

  4 in total