Characterization of temperature dependent mechanical behavior of cartilage.

YongSeok Chae1, Guillermo Aguilar, Enrique J Lavernia, Brian J F Wong.   

Abstract

BACKGROUND AND OBJECTIVES: Few quantitative studies have investigated the temperature dependent viscoelastic properties of cartilage tissue. Cartilage softens and can be reshaped when heated using laser, RF, or contact heating sources. The objectives of this study were to: (1) measure temperature dependent flexural storage moduli and mechanical relaxation in cartilage, (2) determine the impact of tissue water content and orientation on these mechanical properties, and (3) use these measurements to estimate the activation energy associated with the mechanical relaxation process. STUDY DESIGN/
MATERIALS AND METHODS: Porcine nasal septal cartilage specimens (30 x 10 x 2 mm) were deformed using a single cantilever arrangement in a dynamic thermomechanical analyzer. Stress relaxation measurements were made at discrete temperatures ranging from 25 to 70 degrees C in response to cyclic deformation (within the linear viscoelastic region). The time and temperature dependent behavior of cartilage was measured using frequency multiplexing techniques (10-64 Hz), and these results were used to estimate the activation energy for the phase change using the Williams-Landel-Ferry (WLF) equation and the Arrhenius kinetic equation. In addition, the effect of tissue orientation was examined with specimens oriented in both transverse and longitudinal directions at room temperature.
RESULTS: The storage moduli of porcine cartilage decreased with increasing temperature, and a critical change in mechanical properties was observed between 58 and 60 degrees C with a reduction in the storage modulus by 85-90%. The shift of the stress relaxation behavior from viscoelastic solid to viscoelastic liquid was observed between 50 and 57 degrees C and likely corresponds to the transition temperature region in which structural changes in the tissue occur. The storage moduli for transverse and longitudinally oriented specimens were 19-22 and 14-16 MPa, respectively at ambient temperature. Reducing the water content (<10% mass loss) by allowing it to dry under ambient conditions resulted in reduction in the storage modulus by 31-36%. The activation energy associated with the mechanical relaxation of cartilage was 147 kJ/mole at 60 degrees C. This value was calculated by measuring stress-strain relationship under conditions where linear viscoelastic behavior was observed (0.09-0.15% of strain) within the transition temperature region (58-60 degrees C).
CONCLUSIONS: The anisotropic mechanical behavior of cartilage was quantitatively analyzed in the transversely and longitudinally oriented specimens. Viscoelastic behavior appeared to be strongly dependent on the water content. Using empirically determined estimates of the transition zone temperature range accompanying stress relaxation, the activation energy for stress relaxation was calculated using time and temperature superposition theory and WLF equation. Further investigation of the molecular changes, which occur during laser irradiation, may assist in understanding the thermal and mechanical behavior of cartilage and how the reshaping process might to be optimized. Copyright 2003 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2003        PMID: 12696094     DOI: 10.1002/lsm.10167

Source DB:  PubMed          Journal:  Lasers Surg Med        ISSN: 0196-8092            Impact factor:   4.025


  12 in total

1.  Stabilization of costal cartilage graft warping using infrared laser irradiation in a porcine model.

Authors:  Allen Foulad; Pedram Ghasri; Rohit Garg; Brian Wong
Journal:  Arch Facial Plast Surg       Date:  2010 Nov-Dec

2.  In vivo monitoring of focused ultrasound surgery using local harmonic motion.

Authors:  Laura Curiel; Rajiv Chopra; Kullervo Hynynen
Journal:  Ultrasound Med Biol       Date:  2008-09-21       Impact factor: 2.998

3.  In vivo laser cartilage reshaping with carbon dioxide spray cooling in a rabbit ear model: a pilot study.

Authors:  Edward C Kuan; Ashley A Hamamoto; Victor Sun; Tony Nguyen; Cyrus T Manuel; Dmitry E Protsenko; Brian J F Wong; J Stuart Nelson; Wangcun Jia
Journal:  Lasers Surg Med       Date:  2014-11-18       Impact factor: 4.025

4.  Effect of Water Content on Enthalpic Relaxations in Porcine Septal Cartilage.

Authors:  Y Chae; D Protsenko; E J Lavernia; B J F Wong
Journal:  J Therm Anal Calorim       Date:  2009-03-01       Impact factor: 4.626

5.  Mechanical properties of porcine cartilage after uniform RF heating.

Authors:  Allison J Zemek; Dmitry E Protsenko; Brian J F Wong
Journal:  Lasers Surg Med       Date:  2012-08-06       Impact factor: 4.025

6.  Thermoforming of tracheal cartilage: viability, shape change, and mechanical behavior.

Authors:  Yongseok Chae; Dmitriy Protsenko; Paul K Holden; Cara Chlebicki; Brian J F Wong
Journal:  Lasers Surg Med       Date:  2008-10       Impact factor: 4.025

7.  Temperature alters solute transport in growth plate cartilage measured by in vivo multiphoton microscopy.

Authors:  Maria A Serrat; Rebecca M Williams; Cornelia E Farnum
Journal:  J Appl Physiol (1985)       Date:  2009-04-16

8.  Minimally invasive ear reshaping with a 1450-nm diode laser using cryogen spray cooling in New Zealand white rabbits.

Authors:  Paul K Holden; Cara Chlebicki; Brian J F Wong
Journal:  Arch Facial Plast Surg       Date:  2009 Nov-Dec

9.  Ex vivo investigations of laser auricular cartilage reshaping with carbon dioxide spray cooling in a rabbit model.

Authors:  Edward C Wu; Victor Sun; Cyrus T Manuel; Dmitriy E Protsenko; Wangcun Jia; J Stuart Nelson; Brian J F Wong
Journal:  Lasers Med Sci       Date:  2013-01-10       Impact factor: 3.161

10.  Effect of Heat Level and Expose Time on Denaturation of Collagen Tissues.

Authors:  İrem Deniz Derman; Esat Can Şenel; Onur Ferhanoğlu; İnci Çilesiz; Murat Kazanci
Journal:  Cell Mol Bioeng       Date:  2020-09-28       Impact factor: 2.321

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.