Literature DB >> 12695193

Microsnare-assisted mechanical removal of intraprocedural distal middle cerebral arterial thromboembolism.

Pieter Fourie1, Ian C Duncan.   

Abstract

Thromboembolic events are potential complications of neurointerventional procedures. The mainstay of therapy for these complications is both supportive therapy and the use of fibrinolytic agents. In some cases, the occluding clot seems to be resistant to fibrinolytic or anti-platelet agents. We herein report our successful attempt at clot removal by using a microsnare to mechanically capture and remove a small resistant organized clot fragment that was occluding one of the post-trifurcation M2 divisions of a middle cerebral artery. This complication occurred during coil embolization of an ipsilateral posterior communicating aneurysm.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12695193      PMCID: PMC8148692     

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  5 in total

1.  Use of glycoprotein IIb-IIIa inhibitor for a thromboembolic complication during Guglielmi detachable coil treatment of an acutely ruptured aneurysm.

Authors:  P P Ng; C C Phatouros; M S Khangure
Journal:  AJNR Am J Neuroradiol       Date:  2001-10       Impact factor: 3.825

2.  Transcatheter snare removal of acute middle cerebral artery thromboembolism: technical case report.

Authors:  B W Chopko; C Kerber; W Wong; B Georgy
Journal:  Neurosurgery       Date:  2000-06       Impact factor: 4.654

3.  Catheter-Directed Intra-Arterial Abciximab Administration for Acute Thrombotic Occlusions during Neurointerventional Procedures.

Authors:  I C Duncan; P A Fourie
Journal:  Interv Neuroradiol       Date:  2004-10-20       Impact factor: 1.610

4.  Local intraarterial fibrinolysis of thromboemboli occurring during endovascular treatment of intracerebral aneurysm: a comparison of anatomic results and clinical outcome.

Authors:  M Cronqvist; L Pierot; A Boulin; C Cognard; L Castaings; J Moret
Journal:  AJNR Am J Neuroradiol       Date:  1998-01       Impact factor: 3.825

5.  Use of abciximab for mediation of thromboembolic complications of endovascular therapy.

Authors:  H J Cloft; O B Samuels; F C Tong; J E Dion
Journal:  AJNR Am J Neuroradiol       Date:  2001-10       Impact factor: 3.825

  5 in total
  10 in total

Review 1.  Mechanical interventions to treat acute stroke.

Authors:  David Fussell; H Christian Schumacher; Philip M Meyers; Randall T Higashida
Journal:  Curr Neurol Neurosci Rep       Date:  2007-01       Impact factor: 5.081

2.  Mechanical thrombectomy for acute stroke.

Authors:  Eric J Versnick; Huy M Do; Greg W Albers; David C Tong; Michael P Marks
Journal:  AJNR Am J Neuroradiol       Date:  2005-04       Impact factor: 3.825

3.  Short- and intermediate-term angiographic and clinical outcomes of patients with various grades of coil protrusions following embolization of intracranial aneurysms.

Authors:  M Abdihalim; S H Kim; A Maud; M F K Suri; N Tariq; A I Qureshi
Journal:  AJNR Am J Neuroradiol       Date:  2011-09-01       Impact factor: 3.825

Review 4.  Clinical Presentation, Imaging, and Management of Complications due to Neurointerventional Procedures.

Authors:  Matthew C Davis; John P Deveikis; Mark R Harrigan
Journal:  Semin Intervent Radiol       Date:  2015-06       Impact factor: 1.513

Review 5.  Beyond the time window of intravenous thrombolysis: standing by or by stenting?

Authors:  Xinfeng Liu
Journal:  Interv Neurol       Date:  2012-05

6.  Transvenous Removal of Glue from Obstructed Straight Sinus during Transarterial Embolization.

Authors:  A Krajina; M Lojik; J Nahlovsky
Journal:  Interv Neuroradiol       Date:  2007-06-27       Impact factor: 1.610

7.  Initial experience with the use of intravenous eptifibatide bolus during endovascular treatment of intracranial aneurysms.

Authors:  H J Yi; R Gupta; T G Jovin; A Tayal; J Genevro; Y Gologorsky; M Horowitz
Journal:  AJNR Am J Neuroradiol       Date:  2006-10       Impact factor: 3.825

8.  Treatment of acute middle cerebral artery occlusion with a Solitaire AB stent: preliminary experience.

Authors:  S Nayak; G Ladurner; M Killer
Journal:  Br J Radiol       Date:  2010-12       Impact factor: 3.039

9.  A device for fast mechanical clot retrieval from intracranial arteries (Phenox clot retriever).

Authors:  Hans Henkes; Jörg Reinartz; Stephan Lowens; Elina Miloslavski; Christian Roth; Wolfgang Reith; Dietmar Kühne
Journal:  Neurocrit Care       Date:  2006       Impact factor: 3.210

10.  Different Rescue Approaches of Migrated Woven Endobridge (WEB) Devices: an Animal Study.

Authors:  Andreas Simgen; Michael Kettner; Philipp Dietrich; Toshiki Tomori; Ruben Mühl-Benninghaus; Pervinder Bhogal; Matthias W Laschke; Michael D Menger; Wolfgang Reith; Umut Yilmaz
Journal:  Clin Neuroradiol       Date:  2020-03-12       Impact factor: 3.649

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.