Literature DB >> 12694824

Routine IMRT verification by means of an automated Monte Carlo simulation system.

Antonio Leal1, Francisco Sánchez-Doblado, Rafael Arráns, Joan Roselló, Ester Carrasco Pavón, Juan Ignacio Lagares.   

Abstract

PURPOSE: A tool to simulate complete intensity-modulated radiation therapy (IMRT) treatments with the Monte Carlo (MC) method has been developed. This application is based on a distribution model to employ as short processing times as possible for an operative verification.
MATERIALS AND METHODS: The Clinical Primus-Siemens Linac beam was simulated with MC, using the EGS4 OMEGA-BEAM code package. An additional home-made program prepares the appropriate parameters for the code, using as input the file sent from the planning system to the linac. These parameters are adapted to the simulation code, making physical and clinical subdivisions of the global simulation of the treatment. Each resultant partition is ordered to a client personal computer in a cluster with 47 machines under a Linux environment. The verification procedure starts delivering the treatment on a plastic phantom containing an ionization chamber. If differences are less than 2%, films are inserted at selected planes in the phantom and the treatment is delivered again to evaluate the relative doses. When matching between treatment planning system (TPS), film, and MC is acceptable, a new evaluation of the patient is then performed between TPS and MC. Three different cases are shown to prove the applicability of the verification model.
RESULTS: Acceptable agreement between the three methods used was obtained. The results are presented using different analysis tools. The actual time employed to simulate the total treatment in each case was no more than 5 h, depending on the number of segments.
CONCLUSIONS: The MC model presented is fully automated, and results can be achieved within the operative time limits. The procedure is a reliable tool to verify any IMRT treatment.

Entities:  

Mesh:

Year:  2003        PMID: 12694824     DOI: 10.1016/s0360-3016(03)00067-1

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  12 in total

1.  Dosimetric impact of motion in free-breathing and gated lung radiotherapy: a 4D Monte Carlo study of intrafraction and interfraction effects.

Authors:  Joao Seco; Greg C Sharp; Ziji Wu; David Gierga; Florian Buettner; Harald Paganetti
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

2.  Three-dimensional conformal planning with low-segment multicriteria intensity modulated radiation therapy optimization.

Authors:  Fazal Khan; David Craft
Journal:  Pract Radiat Oncol       Date:  2014-08-21

3.  Dosimetric and Monte Carlo verification of jaws-only IMRT plans calculated by the Collapsed Cone Convolution algorithm for head and neck cancers.

Authors:  Duong Thanh Tai; Luong Thi Oanh; Nguyen Dong Son; Truong Thi Hong Loan; James C L Chow
Journal:  Rep Pract Oncol Radiother       Date:  2018-11-28

4.  Verification of inverse planning and treatment delivery for segmental IMRT.

Authors:  James L Bedford; Peter J Childs; Alan P Warrington
Journal:  J Appl Clin Med Phys       Date:  2004-04-01       Impact factor: 2.102

5.  Dose perturbation in the radiotherapy of breast cancer patients implanted with the Magna-Site: a Monte Carlo study.

Authors:  Christos Chatzigiannis; Georgia Lymperopoulou; Panayotis Sandilos; Constantinos Dardoufas; Emmanouil Yakoumakis; Evaggelos Georgiou; Pantelis Karaiskos
Journal:  J Appl Clin Med Phys       Date:  2011-01-19       Impact factor: 2.102

6.  Monte Carlo verification of radiotherapy treatments with CloudMC.

Authors:  Hector Miras; Rubén Jiménez; Álvaro Perales; José Antonio Terrón; Alejandro Bertolet; Antonio Ortiz; José Macías
Journal:  Radiat Oncol       Date:  2018-06-27       Impact factor: 3.481

7.  Dosimetric validation and clinical implementation of two 3D dose verification systems for quality assurance in volumetric-modulated arc therapy techniques.

Authors:  Francisco Clemente-Gutiérrez; Consuelo Pérez-Vara
Journal:  J Appl Clin Med Phys       Date:  2015-03-08       Impact factor: 2.102

8.  Monte Carlo dose verification of prostate patients treated with simultaneous integrated boost intensity modulated radiation therapy.

Authors:  Nesrin Dogan; Ivaylo Mihaylov; Yan Wu; Paul J Keall; Jeffrey V Siebers; Michael P Hagan
Journal:  Radiat Oncol       Date:  2009-06-15       Impact factor: 3.481

9.  Evaluation of the efficiency and effectiveness of independent dose calculation followed by machine log file analysis against conventional measurement based IMRT QA.

Authors:  Baozhou Sun; Dharanipathy Rangaraj; Sunita Boddu; Murty Goddu; Deshan Yang; Geethpriya Palaniswaamy; Sridhar Yaddanapudi; Omar Wooten; Sasa Mutic
Journal:  J Appl Clin Med Phys       Date:  2012-09-06       Impact factor: 2.102

10.  Primo software as a tool for Monte Carlo simulations of intensity modulated radiotherapy: a feasibility study.

Authors:  Alessandro Esposito; Sofia Silva; Jorge Oliveira; Joana Lencart; João Santos
Journal:  Radiat Oncol       Date:  2018-05-15       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.