Evaluation of a dual chamber implantable cardioverter defibrillator for the treatment of atrial and ventricular arrhythmias.

Giuseppe Boriani1, Christian Wollmann, Mauro Biffi, Martin Kühl, Andreas Schuchert, Johannes Sperzel, Sascha Stiller, Gianni Gasparini, Dirk Böcker.   

Abstract

Eighty-nine patients with a documented history of atrial tachyarrhythmias or fibrillation (AF) received a cardioverter defibrillator designed to selectively differentiate and treat atrial and ventricular arrhythmias. Twenty-two patients received a coronary sinus lead and, therefore, could use a separate shock vector for selective treatment of atrial tachyarrhythmias/AF. The device is designed to treat tachyarrhythmias with antitachycardia pacing (ATP) and/or shock therapy using an atrial and/or a ventricular shock vector. Patients underwent induction and shock termination of atrial or dual tachyarrhythmias (AF/VF) to verify proper device function and to measure the arrhythmia detection time with enhancements and preventive algorithms programmed On and Off, respectively. Detection time for 329 VF inductions was 2.41 +/- 0.64 seconds with enhancements On and 2.29 +/- 0.47 with enhancements Off (NS). At implant or predischarge, 283 AF and/or AF/VF (121 atrial and 162 atrial/ventricular fibrillation) were induced. Shock conversion efficacy was 89.8% with AF conversion energies ranging from 0.9 to 27 J. Thirteen of the 23 patients had atrial shock conversions using the separate shock vector with an average conversion energy of 1.9 +/- 1.4 J. (range 0.5-5 J). During follow-up the efficacy of ATP on atrial tachyarrhythmias was 59% and the efficacy of delivered shocks on AF was 85%. This new dual chamber cardioverter defibrillator appropriately detected and classified atrial arrhythmias, and shock therapy for AF was highly effective. The detection algorithm differentiated atrial tachyarrhythmia/AF and did not delay VF detection. The separate shock vector converted induced AF with energies ranging from 0.6 to 5 J.

Entities:  

Mesh:

Year:  2003        PMID: 12687868     DOI: 10.1046/j.1460-9592.2003.00072.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  3 in total

1.  Implantable dual-chamber defibrillator for the selective treatment of spontaneous atrial and ventricular arrhythmias: arrhythmia incidence and device performance.

Authors:  Andreas Schuchert; Giuseppe Boriani; Christian Wollmann; Mauro Biffi; Martin Kühl; Johannes Sperzel; Sascha Stiller; Gianni Gasparini; Dirk Böcker
Journal:  J Interv Card Electrophysiol       Date:  2005-03       Impact factor: 1.900

2.  [Sandwiched between the single- and triple-chamber ICD: do we still need the dual-chamber ICD?].

Authors:  C W Israel
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2008-12

3.  Role of Cdkn2a in the Emery-Dreifuss Muscular Dystrophy Cardiac Phenotype.

Authors:  Gloria Pegoli; Marika Milan; Pierluigi Giuseppe Manti; Andrea Bianchi; Federica Lucini; Philina Santarelli; Claudia Bearzi; Roberto Rizzi; Chiara Lanzuolo
Journal:  Biomolecules       Date:  2021-04-06
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.