Literature DB >> 12687846

Inter- and intraday variability in major electrocardiogram intervals and amplitudes in healthy men and women.

Corina D Dota1, Nils Edvardsson, Kajs-Marie Schützer, Eva Lavik Olofsson, Anders Malm, Tomas Morsing, Gunnar Fager.   

Abstract

The ECG may vary during the day (intra-day), and between days (interday), for the same subject. Variability in ECG characteristic measurements between different investigators is well documented and is often large. During days 1-6 of each placebo period of a two-way crossover Phase I study, digital ECGs were recorded at about 8 and 12 AM in 16 healthy volunteers (8 men, 8 women). Two observers independently analyzed leads V2 and V6 using EClysis software. The durations and amplitudes of major ECG waves and the intervals between major electrocardiographic events were analyzed in a mixed model ANOVA, in which subject, observer, time, and day were treated as random factors. The influence of various corrections for heart rate on the variability of QT intervals was investigated. The difference among subjects explained between 44-81% of the total variability in ECG intervals and amplitudes. Overall, inter- and intraday variability was not statistically significant for any variable. The individualized exponential correction of the QT interval for heart rate eliminated the QT interval dependence on the RR interval in all subjects. Changes in T wave morphology and shortening of the QT interval from morning to noon were observed in ten subjects. The interobserver variability was close to zero (SD < 0.005 ms) for all variables except the PQ interval (SD 1.4 ms). The various sources of variability in determinations of ECG wave characteristics should be considered in the design of clinical studies. The use of EClysis software for ECG measurements is this study made the results highly observer independent.

Entities:  

Mesh:

Year:  2003        PMID: 12687846     DOI: 10.1046/j.1460-9592.2003.00050.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  4 in total

1.  T-wave morphology parameters based on principal component analysis reproducibility and dependence on T-offset position.

Authors:  Fabrice Extramiana; Abdeddayem Haggui; Pierre Maison-Blanche; Rémi Dubois; Seiji Takatsuki; Philippe Beaufils; Antoine Leenhardt
Journal:  Ann Noninvasive Electrocardiol       Date:  2007-10       Impact factor: 1.468

2.  Evaluation of QTc Interval Prolongation in Breast Cancer Patients after Treatment with Epirubicin, Cyclophosphamide, and Docetaxel and the Influence of Interobserver Variation.

Authors:  Julian Puppe; Deborah van Ooyen; Jeanne Neise; Fabinshy Thangarajah; Christian Eichler; Stefan Krämer; Roman Pfister; Peter Mallmann; Marina Wirtz; Guido Michels
Journal:  Breast Care (Basel)       Date:  2017-01-18       Impact factor: 2.860

3.  Assessment of QT(c)-prolonging potential of BX471 in healthy volunteers. A 'thorough QT study' following ICH E14 using various QT(c) correction methods.

Authors:  Marc Vandemeulebroecke; Jürgen Lembcke; Herbert Wiesinger; Wolfgang Sittner; Stefanie Lindemann
Journal:  Br J Clin Pharmacol       Date:  2009-09       Impact factor: 4.335

4.  Comparing QT interval variability of semiautomated and high-precision ECG methodologies in seven thorough QT studies-implications for the power of studies intended for definitive evaluation of a drug's QT effect.

Authors:  Karin Meiser; Pierre Jordaan; Sasha Latypova; Borje Darpo
Journal:  Ann Noninvasive Electrocardiol       Date:  2016-12-19       Impact factor: 1.468

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.