Literature DB >> 12687839

Is a cooled tip catheter the solution for the ablation of the cavotricuspid isthmus?

C Scavée1, F Georger, J Jamart, I Mancini, B Collet, D Blommaert, L De Roy.   

Abstract

To test the theoretical superiority of irrigated tip catheters to achieve complete cavotricuspid isthmus block, a 4-mm cooled tip catheter was compared to a conventional 8-mm tip catheter with a double temperature sensor in the cavotricuspid isthmus (CTI) ablation. The study prospectively enrolled 60 patients (47 men, mean 65 +/- 10 years) with common flutter divided in group 1 (n = 30) assigned to an 8-mm tip catheter versus group 2 (n = 30), assigned to an internal circuit, irrigated tip catheter. Linear radiofrequency applications were performed in a point-by-point protocol to achieve complete CTI block. Complete CTI block was achieved in 29 patients in each group. Mean durations of procedure and fluoroscopy were 91 versus 90 and 40 versus 33 minutes in group 1 versus 2, respectively, (NS). The mean number/patient of RF pulses to interrupt atrial flutter was four in group 1 and eight in group 2 (P = 0.034), and 11 and 13, respectively, to interrupt CTI conduction (NS). The total energy delivered was similar in both groups (29,237 vs 23,236 W/s, NS). CTI ablation with a conventional 8-mm tip catheter versus an irrigated tip catheter was associated with similar success rates, procedure duration, and fluoroscopic exposure. The technical complexity of the cooled tip catheter renders it less competitive.

Entities:  

Mesh:

Year:  2003        PMID: 12687839     DOI: 10.1046/j.1460-9592.2003.00043.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  5 in total

1.  Catheter selection for ablation of the cavotricuspid isthmus for treatment of typical atrial flutter.

Authors:  Antoine Da Costa; Yann Jamon; Cécile Romeyer-Bouchard; Jérôme Thévenin; Marc Messier; Karl Isaaz
Journal:  J Interv Card Electrophysiol       Date:  2007-03-01       Impact factor: 1.900

2.  Comparison of a saline irrigated cooled-tip catheter to large electrode catheters with single and multiple temperature sensors for creation of large radiofrequency lesions.

Authors:  Kathleen S McGreevy; James P Hummel; Zou Jiangang; David E Haines
Journal:  J Interv Card Electrophysiol       Date:  2006-01-18       Impact factor: 1.900

Review 3.  [Catheter ablation of typical atrial flutter].

Authors:  Hansjörg Bauerle; T Japha; B-D Gonska
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2008-07-13

4.  Improved Flutter Ablation Outcomes Using a 10mm-tip Ablation Catheter.

Authors:  Tiago Luiz Luz Leiria; Giuliano Becker; Teresa Kus; Vidal Essebag; Tomy Hadjis; Marcio Lerch Sturmer
Journal:  Indian Pacing Electrophysiol J       Date:  2010-12-26

5.  Health-related quality of life in different clinical subgroups with typical AFL who have undergone cavo-tricuspid isthmus ablation.

Authors:  Javier García Seara; Francisco Gude; Pilar Cabanas; José L Martínez-Sande; Xesús Fernández López; Antonio Hernández Madrid; Concepción Moro; José R González Juanatey
Journal:  Health Qual Life Outcomes       Date:  2012-08-06       Impact factor: 3.186

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.