Relationship between selected overdrive parameters and the therapeutic outcome and tolerance of atrial overdrive pacing.

Patrick Attuel1, Dejan Danilovic, Karl-Heinz Konz, Johannes Brachmann, Dia el Allaf, Steffen Löscher, Candido Gomes, Thomas Scheibner, Volker Schibgilla, Istvan Szendey, Andreas Hartmann.   

Abstract

There is a paucity of information on the influence of selected overdrive parameters on the clinical efficacy and tolerance of atrial overdrive algorithms to suppress atrial tachyarrhythmias. Data from a completed clinical trial investigating a new DDD+ overdrive algorithm implemented in a permanent pacemaker were analyzed. One-hundred patients with standard pacing indications and atrial tachyarrhythmias were enrolled and followed for 6 months in DDD and 6 months in DDD+ mode in a randomized, crossover fashion. The overdrive step size was programmed at the discretion of the investigators between 4 and 12 beats/min, overdrive plateau length between 10 and 32 beats, and maximum overdrive rate between 100 and 160 beats/min. The effects of DDD+ versus DDD mode on burden and incidence of atrial tachyarrhythmias stored in the mode switch memory were examined as a function of the programmed overdrive parameters. An overdrive step size between 7 and 12 beats/min, and higher a maximum overdrive rate between 121 and 160 beats/min were slightly more effective than lower programmed values, though > 500 randomized, crossover observations would have been necessary to verify statistical significance. Overdrive pacing related symptoms mandated early manual deactivation of overdrive pacing in 4.7% of 85 evaluated patients. Overdrive was disabled without testing tolerability of less aggressive overdrive values. There was no link between patient symptoms and programmed overdrive step size or overdrive plateau length values.

Entities:  

Mesh:

Year:  2003        PMID: 12687824     DOI: 10.1046/j.1460-9592.2003.00028.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  1 in total

Review 1.  Advances in Cardiac Pacing: Arrhythmia Prediction, Prevention and Control Strategies.

Authors:  Mehrie Harshad Patel; Shrikanth Sampath; Anoushka Kapoor; Devanshi Narendra Damani; Nikitha Chellapuram; Apurva Bhavana Challa; Manmeet Pal Kaur; Richard D Walton; Stavros Stavrakis; Shivaram P Arunachalam; Kanchan Kulkarni
Journal:  Front Physiol       Date:  2021-12-02       Impact factor: 4.566

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.