Literature DB >> 12687820

Comparison of the cardiopulmonary response to exercise in recipients of dual sensor DDDR pacemakers Versus a Healthy control group.

Eric Page1, Pascal Defaye, Jean-Luc Bonnet, Catherine Durand, Amel Amblard.   

Abstract

The authors previously have shown in healthy subjects that age related loss of muscular strength did not alter the chronotropic response during treadmill exercise, whether with sudden onset of effort, as in the chronotropic assessment exercise protocol (CAEP) or more gradual effort as in the Harbor exercise protocol. This study was performed to verify that in patients suffering from chronotropic insufficiency, and in absence of other effort-limiting disorders, "physiologic" pacing enables a cardiorespiratory response comparable to that of age-matched healthy subjects. Furthermore, the aim of the study was to confirm that the response of a new dual sensor-based pacing system was properly adapted to the metabolic demand, whether during CAEP or during Harbor test, by subjecting patients to both protocols. All study participants were able to undergo treadmill exercise testing, had normal cardiopulmonary function tests at rest, and no cardiac, muscular, or pulmonary disease. A healthy group (control) included 16 subjects (mean age 70.4 +/- 3.9 years), and the test group (pacemaker [PM] included 9 subjects (mean age 67.1 +/- 10.8 years) permanently paced for isolated chronotropic insufficiency with a dual sensor pacing system. All subjects underwent CAEP and Harbor tests with measurements of gas exchange, 24 hours apart, in randomized order. All subjects reached an appropriate level of exercise, as expressed by mean lactate plasma concentrations, which were slightly higher in the control than the PM group during CAEP (4.9 +/- 1.9 vs 3.7 +/- 1.9 mmol/L, NS) and Harbor (5.3 +/- 1.9 vs. 3.8 +/- 1.8 mmol/L, P < 0.05) tests. No statistical difference was observed in VO2 and VE at peak exercise between the two groups during either test. In the PM group, heart rate at peak exercise and metabolic reserve slope were higher during the CAEP than the Harbor protocol. These two measurements were significantly lower than in the control group. The PM group also had lower plasma lactate concentrations and dyspnea/fatigue scores. The Harbor test seems less suitable than the CAEP test to study the chronotropic response of pacemakers with dual sensors during exercise. A high performance of the new dual sensor-based pulse generator was confirmed in this physically fit patient population, whose peak heart rate was considerably higher than in other similar studies.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12687820     DOI: 10.1046/j.1460-9592.2003.00024.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  1 in total

1.  Assessment of adaptive rate response provided by accelerometer, minute ventilation and dual sensor compared with normal sinus rhythm during exercise: a self-controlled study in chronotropically competent subjects.

Authors:  Yuanyuan Cao; Yiqun Zhang; Yangang Su; Jin Bai; Wei Wang; Junbo Ge
Journal:  Chin Med J (Engl)       Date:  2015-01-05       Impact factor: 2.628

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.