Limits of diagnostic accuracy of anti-hepatitis C virus antibodies detection by ELISA and immunoblot assay.

Anatoly P Suslov1, Stanislav N Kuzin, Tatiana V Golosova, Nina V Shalunova, Nikolai A Malyshev, Natalia V Sadikova, Lubov M Vavilova, Anna V Somova, Elena E Musina, Maria V Ivanova, Tatiana T Kipor, Igor M Timonin, Lubov E Kuzina, Mihail A Godkov, Alexei I Bajenov, Vladimir G Nesterenko.   

Abstract

When human sera samples are tested for anti-hepatitis C virus (HCV) antibodies using different ELISA kits as well as immunoblot assay kits discrepant results often occur. As a result the diagnostics of HCV infection in such sera remains unclear. The purpose of this investigation is to define the limits of HCV serodiagnostics. Overall 7 different test kits of domestic and foreign manufacturers were used for the sampled sera testing. Preliminary comparative study, using seroconversion panels PHV905, PHV907, PHV908 was performed and reference kit was chosen (Murex anti-HCV version 4) as the most sensitive kit on the base of this study results. Overall 1640 sera samples have been screened using different anti-HCV ELISA kits and 667 of them gave discrepant results in at least two kits. These sera were then tested using three anti-HCV ELISA kits (first set of 377 samples) or four anti-HCV ELISA kits (second set of 290 samples) at the conditions of reference laboratory. In the first set 17.2% samples remained discrepant and in the second set - 13.4%. "Discrepant" sera were further tested in RIBA 3.0 and INNO-LIA immunoblot confirmatory assays, but approximately 5-7% of them remained undetermined after all the tests. For the samples with signal-to-cutoff ratio higher than 3.0 high rate of result consistency by reference, ELISA routing and INNO-LIA immunoblot assay was observed. On the other hand the results of tests 27 "problematic" sera in RIBA 3.0 and INNO-LIA were consistent only in 55.5% cases. Analysis of the antigen spectrum reactive with antibodies in "problematic" sera, demonstrated predominance of Core, NS3 and NS4 antigens for sera, positive in RIBA 3.0 and Core and NS3 antigens for sera, positive in INNO-LIA. To overcome the problem of undetermined sera, methods based on other principles, as well as alternative criteria of HCV infection diagnostics are discussed.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12687261

Source DB:  PubMed          Journal:  Russ J Immunol        ISSN: 1028-7221


  1 in total

Review 1.  Enzyme-linked immunosorbent/chemiluminescence assays, recombinant immunoblot assays and nucleic acid tests in the diagnosis of HCV infection.

Authors:  Robério Amorim de Almeida Pondé
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2013-05-11       Impact factor: 3.267

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.