Literature DB >> 12685608

Solid-phase extraction and sample stacking-micellar electrokinetic capillary chromatography for the determination of multiresidues of herbicides and metabolites.

R Carabias-Martínez1, E Rodríguez-Gonzalo, P Revilla-Ruiz, J Domínguez-Alvarez.   

Abstract

Micellar electrokinetic capillary chromatography (MEKC) with diode array detection was used for the separation of 13 compounds (eight herbicides widely used in agriculture: metribuzin, lenacil, ethofumesate, atrazine, terbutryn, isoproturon, chlorotoluron and linuron, and five of their principal degradation products; namely, deethylatrazine, 2-hydroxyatrazine, deethyl-2-hydroxyatrazine, deisopropylatrazine and 3-chloro-4-methylphenylurea). Peak separation for the 13 analytes was not successful when a single surfactant system was employed, neither sodium dodecyl sulfate (SDS) nor dioctyl sulfosuccinate (DOSS) sodium salt. However, a mixture of these herbicides was successfully separated using a mixed micellar system involving SDS-DOSS in less than 14 min. An application study of an on-line concentration technique for MEKC was carried out to enhance sensitivity. The optimized on-line stacking procedure consisted simply of the addition of 50 mM of sodium chloride to the injection sample, the stacking effect being more intensive as analyte polarity increased. When this stacking procedure was combined with an off-line sample preconcentration step, based on solid-phase extraction, analytes could be detected in the ppb range. The whole method was applied to ultra-high-quality and natural waters. Linear relationships between the analytical signal and the initial analyte concentration were found to be independent of the type of water, except for the more polar analytes for which small differences were observed.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12685608     DOI: 10.1016/s0021-9673(02)01969-6

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  2 in total

1.  Integrated Multi-process Microfluidic Systems for Automating Analysis.

Authors:  Weichun Yang; Adam T Woolley
Journal:  JALA Charlottesv Va       Date:  2010-06-01

2.  Behaviour and quantification studies of terbacil and lenacil in environmental samples using cyclic and adsorptive stripping voltammetry at hanging mercury drop electrode.

Authors:  T Thriveni; J Rajesh Kumar; D Sujatha; N Y Sreedhar
Journal:  Environ Monit Assess       Date:  2006-09-07       Impact factor: 3.307

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.