[Accuracy of renal volume assessment in children by three-dimensional sonography].

G A Fritz1, M Riccabona, G Bohdal, F Quehenberger.   

Abstract

PURPOSE: Prospective evaluation of the accuracy of three-dimensional ultrasound (3DUS) to assess the renal parenchymal volume.
MATERIALS AND METHODS: CT, MRI, 2DUS and 3DUS were used to measure the renal volume in 40 patients (range: neonate to 17 years; mean age: 8.95 years). The 3DUS was determined with a Voluson 730 (Kretztechnik, GE) or an external 3D-system (EchoTech, GE) using electromagnetic positioning sensors attached to conventional 2DUS-equipment. The 2DUS volume was calculated with the ellipsoid equation and the 3DUS volume computed with the system integrated software. For CT and MRI, planimetric analysis was used to determine the renal parenchymal volume, whereby the dilated collecting system of a hydronephrosis was subtracted to obtain the real renal parenchymal volume. The results of 2DUS and 3DUS were compared to the results of CT and MRI, and inter- and intraobserver variabilities were calculated.
RESULTS: In 74 of 77 kidneys, the 3DUS study was of diagnostic quality. The accuracy of the 3DUS volumes compared well to the CT and MRI volumes with a mean difference of -1.8 +/- 4.6 % versus a mean difference of -2.4 +/- 15.4 % for 2DUS. In normal kidneys, the accuracy was -2.6 +/- 4.4 % for 3DUS and -3.8 +/- 14.7 % for 2DUS. In hydronephrosis, the accuracy was +4.0 +/- 5.9 % and +9.6 +/- 21.3 %, respectively, indicating that 3DUS is more accurate than 2DUS, particularly in kidneys with a dilated collecting system. Inter- and intraobserver variabilities were +/- 7.3 % and +/- 5.3 %.
CONCLUSION: For assessing the renal parenchymal volume in children, 3DUS is feasible and comparable to CT and MRI.

Entities:  

Mesh:

Year:  2003        PMID: 12677511     DOI: 10.1055/s-2003-38442

Source DB:  PubMed          Journal:  Rofo        ISSN: 1438-9010


  10 in total

Review 1.  [Advances in pediatric sonography].

Authors:  K Darge; M Beer
Journal:  Radiologe       Date:  2003-10       Impact factor: 0.635

2.  [Modern ultrasound technologies and their application in pediatric urinary tract imaging].

Authors:  K Darge; A Heidemeier
Journal:  Radiologe       Date:  2005-12       Impact factor: 0.635

3.  Three-dimensional ultrasound reconstruction of the pelvicaliceal system: an in-vitro study.

Authors:  Khurshid R Ghani; James Pilcher; Uday Patel; David Rowland; Daruish Nassiri; Ken Anson
Journal:  World J Urol       Date:  2008-06-07       Impact factor: 4.226

4.  Are renal volumes measured by magnetic resonance imaging and three-dimensional ultrasound in the term neonate comparable?

Authors:  Alison L Kent; Rajeev Jyoti; Cameron Robertson; Lisa Gonsalves; Sandra Meskell; Bruce Shadbolt; Michael C Falk
Journal:  Pediatr Nephrol       Date:  2010-05       Impact factor: 3.714

5.  Sonographic assessment of normal kidney dimensions in the first year of life--a study of 992 healthy infants.

Authors:  Ana Vujic; Jovan Kosutic; Radovan Bogdanovic; Sergej Prijic; Biljana Milicic; Zoran Igrutinovic
Journal:  Pediatr Nephrol       Date:  2007-03-31       Impact factor: 3.714

Review 6.  Potential role of 3DUS in infants and children.

Authors:  Michael Riccabona
Journal:  Pediatr Radiol       Date:  2011-04-27

7.  Renal MRI findings and their clinical associations in nephropathia epidemica: analysis of quantitative findings.

Authors:  A Paakkala; P Dastidar; P Ryymin; H Huhtala; J Mustonen
Journal:  Eur Radiol       Date:  2004-06-05       Impact factor: 5.315

8.  Potential applications of three-dimensional ultrasound in the pediatric urinary tract: pictorial demonstration based on preliminary results.

Authors:  M Riccabona; G Fritz; E Ring
Journal:  Eur Radiol       Date:  2003-10-03       Impact factor: 5.315

9.  A new serum cystatin C formula for estimating glomerular filtration rate in newborns.

Authors:  Milena Treiber; Breda Pečovnik Balon; Maksimiljan Gorenjak
Journal:  Pediatr Nephrol       Date:  2015-05-09       Impact factor: 3.714

Review 10.  Editorial review: pediatric 3D ultrasound.

Authors:  Michael Riccabona
Journal:  J Ultrason       Date:  2014-03-30
  10 in total