Using the volumetric effect of a finite-sized detector for routine quality assurance of multileaf collimator leaf positioning.

Yong Yang1, Lei Xing.   

Abstract

Intensity modulated radiation therapy (IMRT) is an advanced form of radiation therapy and promises to improve dose conformation while reducing the irradiation to the sensitive structures. The modality is, however, more complicated than conventional treatment and requires much more stringent quality assurance (QA) to ensure what has been planned can be achieved accurately. One of the main QA tasks is the assurance of positioning accuracy of multileaf collimator (MLC) leaves during IMRT delivery. Currently, the routine quality assurance of MLC in most clinics isbeing done using radiographic films with specially designed MLC leaf sequences. Besides being time consuming, the results of film measurements are difficult to quantify and interpret. In this work, we propose a new and effective technique for routine MLC leaf positioning QA. The technique utilizes the fact that, when a finite-sized detector is placed under a leaf, the relative output of the detector will depend on the relative fractional volume irradiated. A small error in leaf positioning would change the fractional volume irradiated and lead to a deviation of the relative output from the normal reading. For a given MLC and detector system, the relation between the relative output and the leaf displacement can be easily established through experimental measurements and used subsequently as a quantitative means for detecting possible leaf positional errors. The method was tested using a linear accelerator with an 80-leaf MLC. Three different locations, including two locations on central plane (X1 = X2 = 0) and one point on an off-central plane location (X1 = -7.5, X = 7.5), were studied. Our results indicated that the method could accurately detect a leaf positional change of approximately 0.1 mm. The method was also used to monitor the stability of MLC leaf positioning for five consecutive weeks. In this test, we intentionally introduced two positional errors in the testing MLC leaf sequences: -0.2 mm and 1.2 mm. The technique was found to be robust and could detect the positional inaccuracy in each week's test. The influence of other possible error sources, including the ion chamber placement, jaw settings, gantry and collimator angle read-outs, and the positioning errors of the adjacent leaves, on detection accuracy were also investigated. The principle of our method is independent of the types of the MLC and the detector and may have significant practical implications in facilitating routine MLC QA for IMRT delivery.

Mesh:

Year:  2003        PMID: 12674244     DOI: 10.1118/1.1543150

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  A method to enhance spatial resolution of a 2D ion chamber array for quality control of MLC.

Authors:  Rogelio Diaz Moreno; Daniel Venencia; Edgardo Garrigo; Yakov Pipman
Journal:  J Appl Clin Med Phys       Date:  2011-11-15       Impact factor: 2.102

2.  Physical and Dosimetric Aspect of Euromechanics Add-on Multileaf Collimator on Varian Clinac 2100 C/D.

Authors:  S A Rohani; S R Mahdavi; A Mostaar; S Ueltzhöffer; R Mohammadi; Gh Geraily
Journal:  J Biomed Phys Eng       Date:  2019-02-01

3.  Compensators: an alternative IMRT delivery technique.

Authors:  Sha X Chang; Timothy J Cullip; Katharin M Deschesne; Elizabeth P Miller; Julian G Rosenman
Journal:  J Appl Clin Med Phys       Date:  2004-07-01       Impact factor: 2.102

4.  Dosimetric characteristics of a cubic-block-piled compensator for intensity-modulated radiation therapy in the Pinnacle radiotherapy treatment planning system.

Authors:  Koji Sasaki; Yasunori Obata
Journal:  J Appl Clin Med Phys       Date:  2006-06-16       Impact factor: 2.102