A Monte Carlo study of IMRT beamlets in inhomogeneous media.

Andrew O Jones1, Indra J Das, Frederick L Jones.   

Abstract

Intensity Modulated Radiation Therapy (IMRT) has trended toward smaller multiple radiation fields thereby increasing the resolution of the intensity map. Vendors have introduced multileaf collimators with beam apertures of 0.5 cm and less. The beam characteristics of these smaller fields have not been adequately assessed, especially in the presence of inhomogeneities. Most dosimetric devices have significant limitations due to finite size, dose rate, and energy dependence. We studied the effect of inhomogeneities on small beamlets. The 6, 15, and 24 MV beams were modeled using the EGSnrc Monte Carlo code. Point source beams of circular field sizes 0.5, 1.0, 3.0, 5.0, and 10 cm were simulated in a water phantom at 100 SSD. A 3 cm inhomogeneity of lung tissue was incorporated between 3 and 6 cm in the phantom. The depth dose curves and profiles were compared by beam size and density of the inhomogeneity. The Monte Carlo simulations show that for small fields a marked dose decrease in the presence of low-density media due to the lack of lateral electronic equilibrium is observed. As the density and field size increase, the dose reduction is less pronounced and for the 10 cm field there is an increased dose as expected due to lack of attenuation. This data suggests that current TPS may dramatically over- or underestimate the dose in inhomogeneous media for small field sizes that are used for IMRT.

Mesh:

Year:  2003        PMID: 12674228     DOI: 10.1118/1.1539040

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  6 in total

1.  Evaluation of dose calculations accuracy of a commercial treatment planning system for the head and neck region in radiotherapy.

Authors:  Mohammad Taghi Bahreyni Toossi; Bagher Farhood; Shokouhozaman Soleymanifard
Journal:  Rep Pract Oncol Radiother       Date:  2017-08-18

2.  Study of efficiency in five-field and field-by-field intensity modulated radiation therapy (IMRT) plan using DOSXYZnrc Monte Carlo code.

Authors:  Sitti Yani; Indra Budiansah; Mohamad Fahdillah Rhani; Freddy Haryanto
Journal:  Rep Pract Oncol Radiother       Date:  2020-04-27

Review 3.  Monte Carlo methods for device simulations in radiation therapy.

Authors:  Hyojun Park; Harald Paganetti; Jan Schuemann; Xun Jia; Chul Hee Min
Journal:  Phys Med Biol       Date:  2021-09-14       Impact factor: 4.174

Review 4.  Computed tomography imaging parameters for inhomogeneity correction in radiation treatment planning.

Authors:  Indra J Das; Chee-Wai Cheng; Minsong Cao; Peter A S Johnstone
Journal:  J Med Phys       Date:  2016 Jan-Mar

5.  Percentage depth dose evaluation in heterogeneous media using thermoluminescent dosimetry.

Authors:  L A R da Rosa; S C Cardoso; L T Campos; V G L Alves; D V S Batista; A Facure
Journal:  J Appl Clin Med Phys       Date:  2010-01-28       Impact factor: 2.102

6.  Correlation between target volume and electron transport effects affecting heterogeneity corrections in stereotactic body radiotherapy for lung cancer.

Authors:  Yuichi Akino; Indra J Das; Higinia R Cardenes; Colleen M Desrosiers
Journal:  J Radiat Res       Date:  2014-02-11       Impact factor: 2.724

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.