| Literature DB >> 12672625 |
K Kothari1, S Suresh, H D Sarma, V Meera, M R A Pillai.
Abstract
A new procedure for labeling hydroxyapatite (HA) particles with 188Re for radiation synovectomy is described and standardized. The particles were labeled with 188Re in high yields (99%) in acidic medium. HA particle size remained unaffected by reaction conditions as checked by laser diffraction particle analyzer. 188Re-HA was found to be stable retaining 99% radiochemical purity after 4 days when stored in ascorbic acid solution (10mg/ml, pH 5). Intra-articular injection in rats revealed approximately 98% retention of 188Re-HA in the knee after 48-h pi.Entities:
Mesh:
Substances:
Year: 2003 PMID: 12672625 DOI: 10.1016/s0969-8043(03)00028-9