Isotopic metrology of carbon dioxide. II. Effects of ion source materials, conductance, emission, and accelerating voltage on dual-inlet cross contamination.

R Michael Verkouteren1, Sergey Assonov, Donna B Klinedinst, Willi A Brand.   

Abstract

We report high-precision isotopic carbon dioxide measurements, made before and after ion source modification to gas isotope ratio mass spectrometry (IRMS) instruments. Measurement protocols were designed to explore the effects of ion source material substitution, source conductance, inlet pressure, electron emission, acceleration potential, and inlet changeover equilibration time. After modification of the IRMS instruments at the National Institute of Standards and Technology (NIST) and the Max-Planck-Institute for Chemistry (MPI-Mainz), immediate changes were observed. At NIST, measurements were no longer sensitive to inlet equilibration times greater than 15 s, and different settings of ion source conductance resulted in delta(13)C shifts of about 0.04 per thousand per 10 per thousand measurement difference between sample and reference, a five-fold improvement. No significant changes in machine performance were observed after a month of use. After a year, performance had degraded slightly, but was controlled by ion source cleaning and the use of low-energy ion acceleration to minimize sputtering. At MPI-Mainz, results were very similar. We report cross-contamination coefficients measured since 1996, and discuss the role of adsorption, ion implantation, and sputtering on cross contamination in mass spectrometry systems. We recommend that users of high-precision IRMS instruments test for and minimize the effects described.

Entities:  

Year:  2003        PMID: 12672130     DOI: 10.1002/rcm.906

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  2 in total

1.  Physical model for multi-point normalization of dual-inlet isotope ratio mass spectrometry data.

Authors:  Abneesh Srivastava
Journal:  Anal Bioanal Chem       Date:  2022-06-01       Impact factor: 4.478

2.  Determination of the triple oxygen and carbon isotopic composition of CO2 from atomic ion fragments formed in the ion source of the 253 Ultra high-resolution isotope ratio mass spectrometer.

Authors:  Getachew A Adnew; Magdalena E G Hofmann; Dipayan Paul; Amzad Laskar; Jakub Surma; Nina Albrecht; Andreas Pack; Johannes Schwieters; Gerbrand Koren; Wouter Peters; Thomas Röckmann
Journal:  Rapid Commun Mass Spectrom       Date:  2019-09-15       Impact factor: 2.419

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.