Literature DB >> 12668080

Rapid and sensitive high-performance liquid chromatographic determination of four cephalosporin antibiotics in pharmaceuticals and body fluids.

V F Samanidou1, E A Hapeshi, I N Papadoyannis.   

Abstract

A rapid, accurate and sensitive method has been developed and validated for the quantitative simultaneous determination of four cephalosporins, cephalexin and cefadroxil (first-generation), cefaclor (second-generation) and cefataxim (third-generation), in pharmaceuticals as well as in human blood serum and urine. A Spherisorb ODS-2 250 x 4-mm, 5-microm analytical column was used with an eluting system consisting of a mixture of acetate buffer (pH 4.0)-CH(3)OH 78-22% (v/v) at a flow-rate 1.2 ml/min. Detection was performed with a variable wavelength UV-Vis detector at 265 nm resulting in limit of detection of 0.2 ng for cefadroxil and cephalexin, but only 0.1 ng for cefotaxime and cefaclor per 20-microl injection. Hydrochlorothiazide (HCT) (6-chloro-3,4-dihydro-7 sulfanyl-2H-1,2,4-benzothiadiazine-1-1-dioxide) was used as internal standard at a concentration of 2 ng/microl. A rectilinear relationship was observed up to 8, 5, 12 and 35 ng/microl for cefadroxil, cefotaxime, cefaclor, cephalexin, respectively. Analysis time was less than 7 min. The statistical evaluation of the method was examined by means of within-day repeatability (n=8) and day-to-day precision (n=9) and was found to be satisfactory with high accuracy and precision. The method was applied to the determination of the cephalosporins in commercial pharmaceuticals and in biological fluids: human blood serum after solid-phase extraction and urine simply after filtration and dilution. Recovery of analytes in spiked samples was in the range from 76.3 to 112.0%, over the range of 1-8 ng/microl.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12668080     DOI: 10.1016/s1570-0232(02)01040-1

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  5 in total

1.  Polarographic determination of certain cephalosporins in pharmaceutical preparations.

Authors:  A R Guru Prasad; V S Rao
Journal:  Res Pharm Sci       Date:  2010-01

2.  Determination of Cephalexin Monohydrate in Pharmaceutical Dosage Form by Stability-Indicating RP-UFLC and UV Spectroscopic Methods.

Authors:  Sagar Suman Panda; Bera V V Ravi Kumar; Rabisankar Dash; Ganeswar Mohanta
Journal:  Sci Pharm       Date:  2013-07-31

3.  Simultaneous pharmacokinetic assessment of cefadroxil and clavulanic acid in human plasma by LC-MS and its application to bioequivalence studies.

Authors:  Janaki Sankarachari Krishnan Nagarajan; Chandran Sathish Vimal; Renjith George; Anil Dubala
Journal:  J Pharm Anal       Date:  2013-02-26

4.  A Rapid, Validated RP-HPLC Method for the Simultaneous Determination of Cleaning Validation and Cross-Contamination of 12 Beta-Lactam Compounds.

Authors:  Harshal Kanubhai Trivedi; Nayan Kshtri; Mukesh C Patel
Journal:  Sci Pharm       Date:  2012-11-17

5.  Investigation of early antibiotic use in pediatric patients with acute respiratory infections by high-performance liquid chromatography.

Authors:  Pham Van Toi; Khanh V Doan; Ngo Ngọc Quang Minh; Pham Nguyen Phuong; Menno D de Jong; H Rogier van Doorn; Thomas Pouplin
Journal:  Biomed Chromatogr       Date:  2019-11-12       Impact factor: 1.911

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.