| Literature DB >> 12668069 |
B L Kolte1, B B Raut, A A Deo, M A Bagool, D B Shinde.
Abstract
A robust, accurate and sensitive high-performance liquid chromatographic method for the determination of rosiglitazone (I) in human plasma has been developed. Pioglitazone (II) was used as internal standard. Both I and II are extracted from plasma using a liquid-liquid extraction procedure. Isocratic separation of I and II is carried out using a reversed-phase Zorbax SB C(18), 15-cm column with mobile phase consisting of methanol and a mixed phosphate buffer (10 mM monobasic sodium phosphate and dibasic sodium phosphate, pH adjusted to 2.6 with ortho-phosphoric acid) in the ratio 30:70 (v/v) and quantified by UV detection at 245 nm. Linearity was established over the range 5-1250 ng/ml using 1 ml human plasma. The method is specific, the endogenous components in plasma do not interfere with I and II. C.V. (%) of intra-day samples is less than 5.0% at four concentrations tested namely 5, 10, 500 and 1000 ng/ml. Similarly, over the same nominal concentrations, the precision of inter-day (5 days) samples also results in C.V. (%) less than 5.0%. The recoveries of I and II from human plasma were about 79 and 60%, respectively. This method can be used for routine clinical monitoring of I.Entities:
Mesh:
Substances:
Year: 2003 PMID: 12668069 DOI: 10.1016/s1570-0232(02)01011-5
Source DB: PubMed Journal: J Chromatogr B Analyt Technol Biomed Life Sci ISSN: 1570-0232 Impact factor: 3.205