Literature DB >> 12665698

First all-solid pediatric phantom for dual X-ray absorptiometry measurements in infants.

Jean-Charles Picaud1, François Duboeuf, Vey Vey-Marty, Pierre Delams, Oliver Claris, Bernard-Louis Salle, Jacques Rigo.   

Abstract

Manufacturer-supplied lumbar spine phantoms are normally used for quality control of dual X-ray absorptiometry (DXA) instruments. Presently, there is no pediatric phantom for whole-body mineralization and softtissue composition DXA measurements. We designed blocks of acrylic (for fat mass), polyvinyl chloride (for lean mass), and aluminum (for bone mass) whose combination provides five whole-body phantoms ("Inphants") that mimic body weight and composition during the first year of life and help solve problems that require repeated scans in stable conditions. Inphants were scanned using an Hologic QDR 2000. Comparisons were made between values obtained with and without the table pad, using infant software. Then we compared data obtained using infant and adult softwares successively in the same phantoms. The table pad significantly influenced DXA measurements. We observed significant differences in fat mass (p = 0.04) and lean mass (p = 0.03) with the smaller Inphant (3 kg) and in bone mineral content (BMC) (p = 0.02) with the larger Inphant (13 kg). BMC was three to five times lower with adult than with infant software. Adult software yielded systematically significantly lower fat masses but higher lean masses than infant software. Because there was no overlap with larger Inphants, we calculated conversion formulae between values of infant and adult software. The results suggest guidelines for scan acquisition and analysis in young subjects.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12665698     DOI: 10.1385/jcd:6:1:17

Source DB:  PubMed          Journal:  J Clin Densitom        ISSN: 1094-6950            Impact factor:   2.963


  3 in total

1.  Quantitative ultrasound applied to metacarpal bone in infants.

Authors:  Francesco Savino; Serena Viola; Stefania Benetti; Simone Ceratto; Valentina Tarasco; Maria Maddalena Lupica; Luca Cordero di Montezemolo
Journal:  PeerJ       Date:  2013-08-27       Impact factor: 2.984

2.  No radiographic wrist damage after treatment to target in recent-onset juvenile idiopathic arthritis.

Authors:  P C E Hissink Muller; W G van Braak; D Schreurs; C M Nusman; S A Bergstra; R Hemke; D Schonenberg-Meinema; J M van den Berg; T W Kuijpers; Y Koopman-Keemink; M A J van Rossum; L W A van Suijlekom-Smit; D M C Brinkman; C F Allaart; R Ten Cate; M Maas
Journal:  Pediatr Rheumatol Online J       Date:  2019-09-04       Impact factor: 3.054

3.  SGA children with moderate catch-up growth are showing the impaired insulin secretion at the age of 4.

Authors:  Ivana Milovanovic; Falucar Njuieyon; Samia Deghmoun; Didier Chevenne; Claire Levy-Marchal; Jacques Beltrand
Journal:  PLoS One       Date:  2014-06-30       Impact factor: 3.240

  3 in total