Literature DB >> 12658337

[Osseous integration of autogenous bone grafts following combined dorso-ventral instrumentation of unstable thoracolumbar spine fractures].

D Briem1, J M Rueger, W Linhart.   

Abstract

OBJECTIVE: It is widely believed that combined dorso-ventral stabilization provides superior mechanic stability in the operative treatment of thoracolumbar spine fractures. Currently there are no data available reflecting the fusion rates in trauma patients following the combined procedure. Aim of this investigation was to study the fusion rates following dorso-ventral stabilization of thoracolumbar spine fractures and the rates of local complications at the donor site.
METHODS: In order to assess fusion and complication rates 30 patients with unstable fractures of the thoracolumbar spine were selected from a consecutive series and investigated in a prospective study. After posterior stabilization with a fixateur interne (USS, Synthes) anterior arthrodesis was performed subsequently by autogenous iliac bone grafting in combination with an osteosynthesis (MACS,Aesculap;VentroFix, Synthes). The osseous integration of the autogenous transplants was measured by CT-scan 12+/-2.4 months after surgery.
RESULTS: The evaluation of the radiographic and CT data revealed a fusion rate of 77% (23/30) one year after surgery. These findings were accompanied by minor complications at the donor site in 37% (11/30).
CONCLUSION: Our experiences with autogenous spine grafting gave evidence that a reliable osseus integration can not be expected in all of the cases. Furthermore one has to consider a high rate of local complications. Therefore alternative procedures such as the use of cages will be of increasing influence in the surgical treatment of thoracolumbar spine fractures.

Entities:  

Mesh:

Year:  2003        PMID: 12658337     DOI: 10.1007/s00113-002-0508-2

Source DB:  PubMed          Journal:  Unfallchirurg        ISSN: 0177-5537            Impact factor:   1.000


  16 in total

1.  [Bone grafts endoscopically applied to the spine Ergebnisse der anterioren Fusion und therapeutische Konsequenzen].

Authors:  D Briem; J Windolf; W Lehmann; P G C Begemann; N M Meenen; J M Rueger; W Linhart
Journal:  Unfallchirurg       Date:  2004-12       Impact factor: 1.000

2.  Mid-term results of PLIF/TLIF in trauma.

Authors:  Rene Schmid; Dietmar Krappinger; Michael Blauth; Anton Kathrein
Journal:  Eur Spine J       Date:  2010-10-31       Impact factor: 3.134

3.  [Titanium vertebral body replacement of adjustable size. A prospective clinical trial].

Authors:  U Lange; S Edeling; C Knop; L Bastian; C Krettek; M Blauth
Journal:  Unfallchirurg       Date:  2006-09       Impact factor: 1.000

4.  [Radiological comparison between two procedures for ventral spondylodesis: autologous iliac crest bone graft vs bovine bone graft].

Authors:  D Kubosch; J Rohr; K Izadpanah; T O Hammer; N P Südkamp; P C Strohm
Journal:  Unfallchirurg       Date:  2012-10       Impact factor: 1.000

5.  PLIF in thoracolumbar trauma: technique and radiological results.

Authors:  Rene Schmid; Schmid Rene; Dietmar Krappinger; Krappinger Dietmar; Peter Seykora; Seykora Peter; Michael Blauth; Blauth Michael; Anton Kathrein; Kathrein Anton
Journal:  Eur Spine J       Date:  2010-03-09       Impact factor: 3.134

6.  Risk of graft fracture after dorso-ventral thoraco-lumbar spondylodesis: is there a correlation with graft size?

Authors:  David Kubosch; Stefan Milz; Christian Lohrmann; Karsten Schwieger; Lukas Konstantinidis; Christoph M Sprecher; Norbert P Südkamp; Peter C Strohm
Journal:  Eur Spine J       Date:  2011-07-12       Impact factor: 3.134

7.  Anterior vertebral body replacement with a titanium implant of adjustable height: a prospective clinical study.

Authors:  Uta Lange; Sebastian Edeling; Christian Knop; Leonard Bastian; Michael Oeser; Christian Krettek; Michael Blauth
Journal:  Eur Spine J       Date:  2006-05-13       Impact factor: 3.134

8.  Combined posterior-anterior stabilisation of thoracolumbar injuries utilising a vertebral body replacing implant.

Authors:  Christian Knop; T Kranabetter; M Reinhold; M Blauth
Journal:  Eur Spine J       Date:  2009-04-09       Impact factor: 3.134

9.  [Mechanical failure of porous hydroxyapatite ceramics 7.5 years after implantation in the proximal tibial].

Authors:  W Linhart; D Briem; M Amling; J M Rueger; J Windolf
Journal:  Unfallchirurg       Date:  2004-02       Impact factor: 1.000

10.  [Fusion criteria for cages as vertebral body replacement in thoracolumbar fractures].

Authors:  K J Schnake; T Görler; F Kandziora
Journal:  Unfallchirurg       Date:  2014-11       Impact factor: 1.000

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.