Impact of blood and dialysate flow and surface on performance of new polysulfone hemodialysis dialyzers.

S Mandolfo1, F Malberti, E Imbasciati, P Cogliati, A Gauly.   

Abstract

Optimization of hemodialysis treatment parameters and the characteristics of the dialyzer are crucial for short- and long-term outcome of end stage renal disease patients. The new high-flux membrane Helixone in the dialyzer of the FX series (Fresenius Medical Care, Germany) has interesting features, such as the relationship of membrane thickness and capillary diameter which increases middle molecule elimination by convection, as well as higher capillary packing and microondulation to improve the dialysate flow and distribution. Blood flow, dialysate flow and surface area are the main determinants of the performance of a dialyzer, however the impact of each parameter on small and middle molecule clearance in high flux dialysis has not been well explored. In order to find the best treatment condition for the new dialyzer series, we evaluated urea, creatinine, phosphate clearances and reduction rate of beta2-microglobulin in ten stable patients treated with different blood flows (effective Qb 280 and 360 ml/min), dialysate flow (Qd 300 or 500 ml/min) and dialyzer surfaces (1.4 and 2.2 m2, FX60 or FX100). KoA and Kt/V were also calculated. Blood flow, dialysate flow and surface area demonstrated a significant and independent effect on clearance of urea, creatinine and phosphate, as well as on Kt/V. Small solute clearance was stable over the treatment. In contrast to small solutes, reduction rate of beta2-microglobulin was related to increasing dialyzer surface only. The new dialyzer design of the FX series proves highly effective due to improved dialysate distribution and reduced diffusive resistance as shown by the small solute clearance. A high reduction rate of beta2-microglobulin is favored by improved fiber geometry and pore size distribution. These findings have potential long-term benefits for the patient.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12653344     DOI: 10.1177/039139880302600204

Source DB:  PubMed          Journal:  Int J Artif Organs        ISSN: 0391-3988            Impact factor:   1.595


  5 in total

1.  Renal Association Clinical Practice Guideline on Haemodialysis.

Authors:  Damien Ashby; Natalie Borman; James Burton; Richard Corbett; Andrew Davenport; Ken Farrington; Katey Flowers; James Fotheringham; R N Andrea Fox; Gail Franklin; Claire Gardiner; R N Martin Gerrish; Sharlene Greenwood; Daljit Hothi; Abdul Khares; Pelagia Koufaki; Jeremy Levy; Elizabeth Lindley; Jamie Macdonald; Bruno Mafrici; Andrew Mooney; James Tattersall; Kay Tyerman; Enric Villar; Martin Wilkie
Journal:  BMC Nephrol       Date:  2019-10-17       Impact factor: 2.388

2.  Analysis of a single hemodialysis on phosphate removal of the internal fistula patients by mathematical and statistical methods.

Authors:  Qiyao Yu; Yaling Bai; Junxia Zhang; Liwen Cui; Huiran Zhang; Jinsheng Xu; Chao Gao
Journal:  Comput Math Methods Med       Date:  2013-12-24       Impact factor: 2.238

3.  Effect of Membrane Surface Area on Solute Removal Performance of Dialyzers with Fouling.

Authors:  Takayoshi Kiguchi; Hiromi Ito; Akihiro C Yamashita
Journal:  Membranes (Basel)       Date:  2022-07-01

4.  Oxone®-Mediated TEMPO-Oxidized Cellulose Nanomaterial Ultrafiltration and Dialysis Mixed-Matrix Hollow Fiber Membranes.

Authors:  John P Moore; Kristyn Robling; Cristian Romero; Keturah Kiper; Soma Shekar Dachavaram; Peter A Crooks; Jamie A Hestekin
Journal:  Polymers (Basel)       Date:  2020-06-15       Impact factor: 4.329

5.  Real-World Performance of High-Flux Dialyzers in Patients With Hypoalbuminemia.

Authors:  Meijiao Zhou; Linda H Ficociello; Claudy Mullon; Ann Mooney; Don Williamson; Michael S Anger
Journal:  ASAIO J       Date:  2022-01-01       Impact factor: 2.872