Literature DB >> 12652580

High-throughput analysis of telomerase by capillary electrophoresis.

Donald H Atha1, Karen Miller, Anita D Sanow, Jingfan Xu, Jennifer L Hess, Osmond C Wu, Wendy Wang, Sudhir Srivastava, W Edward Highsmith.   

Abstract

The enzyme telomerase is expressed in (85-90)% of all human cancers, but not in normal, non-stem cell somatic tissues. Clinical assays for telomerase in easily obtained body fluids would have great utility as noninvasive, cost-effective methods for the early detection of cancer. The most commonly used method for the detection and quantification of telomerase enzyme activity is the polymerase chain reaction (PCR)-based assay known as the telomerase repeat amplification protocol or TRAP assay. Most of the TRAP assay systems use a slab-gel based electrophoresis system to size and quantify the PCR-amplified extension products. We are developing high-throughput capillary electrophoresis (CE) methods for the analysis of TRAP/PCR products. The TRAP assay was conducted on lysates of the human lung cancer cell line A-549 in reactions containing 5-100 cells. TRAP/PCR products were generated using a fluorescent 4,7,2'4'5'7',-hexachloro-6-carboxyfluorescein(HEX)-labeled TS primer and analyzed on the Applied Biosystems Model 310 CE system using POP4 polymer. After analysis with GeneScan and Genotyper software, the total peak areas of the TRAP ladder extension products were computed using Microsoft Excel. Results were compared with unlabeled TRAP/PCR products analyzed on the Bio-Rad BioFocus 3000 CE system using 6% high molecular weight polyvinylpyrrolidone (HMW PVP) polymer and SYBR Green I dye. Both CE systems were able to resolve the TRAP ladder products with high reproducibility and sensitivity (5-15 cells). With the appropriate robotic sample handling system, these CE methods would enable performing the telomerase TRAP assay with increased sensitivity, reproducibility and automation over slab-gel methods.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12652580     DOI: 10.1002/elps.200390001

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  2 in total

1.  Standards for immunohistochemical imaging: a protein reference device for biomarker quantitation.

Authors:  Donald H Atha; Upender Manne; William E Grizzle; Paul D Wagner; Sudhir Srivastava; Vytas Reipa
Journal:  J Histochem Cytochem       Date:  2010-08-30       Impact factor: 2.479

2.  Analytical validation of telomerase activity for cancer early detection: TRAP/PCR-CE and hTERT mRNA quantification assay for high-throughput screening of tumor cells.

Authors:  John P Jakupciak; Wendy Wang; Peter E Barker; Sudhir Srivastava; Donald H Atha
Journal:  J Mol Diagn       Date:  2004-08       Impact factor: 5.568

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.