Literature DB >> 12651664

A small preoperative test dose of intravenous fentanyl can predict subsequent analgesic efficacy and incidence of side effects in patients due to receive epidural fentanyl.

Kazuyoshi Ueta1, Kiyoshi Takeda, Hisatoshi Ohsumi, Junichi Haruna, Hiromi Shibuya, Takashi Mashimo.   

Abstract

UNLABELLED: Because individual variation is a likely factor affecting both the incidence and severity of side effects and the analgesic efficacy of epidural opioids, assessment of individual variation could be useful in deciding optimal dosage. By evaluating the response to a small test dose of IV fentanyl, we designed this study to predict the degree of pain relief and the incidence of side effects in patients who would be receiving postoperative epidural fentanyl. Before the induction of anesthesia, 50 micro g of fentanyl was administered IV, and 2 min after fentanyl, the patient response was evaluated. Twenty-three patients, who reported nausea, sleepiness, dizziness, sensation of warmth, and other symptoms, were categorized as responders (Group R); the remaining 20 patients were categorized as nonresponders (Group NR). At the completion of surgery, infusion of epidural fentanyl was administered (0.3 mg/d in 0.25% bupivacaine) for 96 h. At postoperative Hours 6 and 24, Group R had significantly lower visual analog scale scores for postoperative pain intensity and required fewer analgesics than Group NR. The incidence of side effects, however, was 74% for Group R and 10% for Group NR (P < 0.05), and side effects were more serious in Group R. This study demonstrates that preoperative administration of a small dose of fentanyl during the induction of anesthesia enables prediction of the analgesic efficacy of postoperative epidural fentanyl and the incidence and severity of side effects. IMPLICATIONS: Preoperative administration of a small dose of fentanyl during the induction of anesthesia enables prediction of the analgesic efficacy of postoperative epidural fentanyl and the incidence and severity of side effects.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12651664     DOI: 10.1213/01.ane.0000055364.39576.ff

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  1 in total

1.  Comparisons of two different doses of fentanyl for procedural analgesia during epidural catheter placement: a double-blind prospective, randomized, placebo-controlled study.

Authors:  Takeshi Yano; Shigeaki Okubo; Hiroaki Naruo; Tatsuma Iwasaki; Isao Tsuneyoshi
Journal:  J Anesth       Date:  2010-09-02       Impact factor: 2.078

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.