Literature DB >> 12650397

Cervical laminoplasty: evaluation of bone bonding of a high porosity hydroxyapatite spacer.

Tetsuhiro Iguchi1, Aritetsu Kanemura, Akira Kurihara, Koichi Kasahara, Shinichi Yoshiya, Minoru Doita, Kotaro Nishida.   

Abstract

OBJECT: The purpose of this study was to evaluate the usefulness of a high-porosity hydroxyapatite (HA) spacer in cervical laminoplasty. Bone-spacer bonding rates, complications associated with the implant, and factors related to bone bonding were examined.
METHODS: The authors evaluated 33 consecutive patients with cervical myelopathy who underwent high-porosity HA spacer-assisted laminoplasty and were followed for at least 1 year (mean 30 months). The results of bone-spacer bonding of the 147 implants were evaluated using computerized tomography (CT) scanning. The symptoms significantly improved in 30 patients. No difference in results was detected between patients with cervical spondylosis and those with ossification of posterior longitudinal ligament. Breakage of seven spacers occurred in four patients without causing neck pain or neurological deficits. There were no other HA spacer-related complications. The spacers became rigidly bound to bone in 61% of the cases, and bone regrowth developed around the spacer in 91%. The rate of bone-spacer bonding increased over time, and the CT-documented attenuation value (Hounsfield unit) of the spacer adjacent to the bone-spacer junction in the group in which union occurred was significantly higher than in the nonunion group.
CONCLUSIONS: High-porosity HA spacer-augmented laminoplasty produced good bonding-related results. Bone bonding continued to progress 1 year after surgery, indicating the good osteoconductive capability of high-porosity HA. To avoid breakage of a spacer, a minimum 7-mm distance between spacers is necessary.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12650397     DOI: 10.3171/spi.2003.98.2.0137

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  6 in total

1.  Intermittent weekly administration of human parathyroid hormone (1-34) improves bone-hydroxyapatite block bonding in ovariectomized rats.

Authors:  Keiji Kamo; Naohisa Miyakoshi; Yuji Kasukawa; Koji Nozaka; Hiroshi Sasaki; Yoichi Shimada
Journal:  J Bone Miner Metab       Date:  2010-04-08       Impact factor: 2.626

2.  Midline-Splitting Open Door Laminoplasty Using Hydroxyapatite Spacers : Comparison between Two Different Shaped Spacers.

Authors:  Jin Hoon Park; Sang Ryong Jeon
Journal:  J Korean Neurosurg Soc       Date:  2012-07-31

3.  Midline Splitting Cervical Laminoplasty Using Allogeneic Bone Spacers: Comparison of Fusion Rates between Cervical Spondylotic Myelopathy and Ossification of Posterior Longitudinal Ligament.

Authors:  Jae Jon Sheen; Sang Ryong Jeon
Journal:  Korean J Neurotrauma       Date:  2014-10-31

4.  Ultraviolet irradiation improves the hydrophilicity and osteo-conduction of hydroxyapatite.

Authors:  Sho Kaneko; Yuji Yamamoto; Kanichiro Wada; Gentaro Kumagai; Yoshifumi Harada; Ryota Yamauchi; Yasuyuki Ishibashi
Journal:  J Orthop Surg Res       Date:  2020-09-18       Impact factor: 2.359

5.  Initial radiological findings utilizing titanium basket for cervical open door laminoplasty.

Authors:  Hidenori Matsuoka; Yukoh Ohara; Yoshiyuki Tomita; Nahoko Kikuchi; Yoshitaka Hirano; Hisaaki Uchikado; Junichi Mizuno
Journal:  Surg Neurol Int       Date:  2017-09-07

6.  Improved bone bonding of hydroxyapatite spacers with a high porosity in a quantitative computed tomography-image pixel analysis: A prospective 1-year comparative study of the consecutive cohort undergoing double-door cervical laminoplasty.

Authors:  Yoshiki Takeoka; Takashi Yurube; Koichiro Maeno; Yutaro Kanda; Ryu Tsujimoto; Kunihiko Miyazaki; Yuji Kakiuchi; Shingo Miyazaki; Zhongying Zhang; Toru Takada; Kotaro Nishida; Minoru Doita; Ryosuke Kuroda; Kenichiro Kakutani
Journal:  JOR Spine       Date:  2020-02-03
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.