Menstrual-cycle dependence of breast parenchyma elasticity: estimation with magnetic resonance elastography of breast tissue during the menstrual cycle.

Jörn Lorenzen1, Ralph Sinkus, Maike Biesterfeldt, Gerhard Adam.   

Abstract

RATIONALE AND
OBJECTIVES: Magnetic resonance elastography (MRE) is a promising diagnostic method that produces images with a contrast proportional to the elasticity of the tissue. This study investigated using MRE the dependence of breast tissue elasticity from the menstrual cycle of healthy volunteers.
METHODS: Five volunteers (age 26-36) without breast disease and contraceptive medication were examined once weekly over 2 menstrual cycles. Examinations were performed with a 1.5 T magnet (ACS-NT, Philips Medical Systems, Best, The Netherlands). Low-frequency mechanical waves (65 Hz) were transmitted into the tissue by an oscillator. By means of a motion-sensitive spin-echo sequence, mechanical waves were displayed within the phase of the MR image and phase images were used to reconstruct the local distribution of elasticity. The elasticity of fibroglandular tissue and adipose breast tissue was analyzed individually, and the median and mean values of elasticity over the menstrual cycle were determined.
RESULTS: All volunteers presented a repeating pattern concerning the elasticity over the 2 cycles. After 5 days of the onset of menses, the median value of elasticity for fibroglandular adipose tissue declined significantly by -29% (P = 0.010). After the second week of the cycle, fibroglandular tissue showed again an increase in elasticity (P = 0.028). The highest median values of elasticity were obtained during days 11 to 23 with an increase of up to 35%. For adipose tissue, only a slight and not significant variation of elasticity during the menstrual cycle was determined.
CONCLUSION: MRE is able to measure a dependence of tissue elasticity on the menstrual cycle.

Entities:  

Mesh:

Year:  2003        PMID: 12649648     DOI: 10.1097/01.RLI.0000059544.18910.BD

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  16 in total

1.  Matrix compliance and RhoA direct the differentiation of mammary progenitor cells.

Authors:  Cecillia Lui; KangAe Lee; Celeste M Nelson
Journal:  Biomech Model Mechanobiol       Date:  2011-12-10

Review 2.  General review of magnetic resonance elastography.

Authors:  Gavin Low; Scott A Kruse; David J Lomas
Journal:  World J Radiol       Date:  2016-01-28

3.  Ultrasonic measurements of breast viscoelasticity.

Authors:  Mallika Sridhar; Michael F Insana
Journal:  Med Phys       Date:  2007-12       Impact factor: 4.071

4.  Menstrual cycle-related fluctuations in breast density measured by using three-dimensional MR imaging.

Authors:  Siwa Chan; Min-Ying L Su; Fu-Ju Lei; Jia-Pei Wu; Muqing Lin; Orhan Nalcioglu; Stephen A Feig; Jeon-Hor Chen
Journal:  Radiology       Date:  2011-08-30       Impact factor: 11.105

5.  Ultrasound elastography using shear wave interference patterns: a finite element study of affecting factors.

Authors:  Pezhman Pasyar; Hossein Arabalibeik; Mohammad Mohammadi; Hassan Rezazadeh; Vahid Sadeghi; Milad Askari; Alireza Mirbagheri
Journal:  Phys Eng Sci Med       Date:  2021-02-16

6.  Breast tissue stiffness estimation for surgical guidance using gravity-induced excitation.

Authors:  Rebekah H Griesenauer; Jared A Weis; Lori R Arlinghaus; Ingrid M Meszoely; Michael I Miga
Journal:  Phys Med Biol       Date:  2017-05-18       Impact factor: 3.609

7.  Elasticity imaging of polymeric media.

Authors:  Mallika Sridhar; Jie Liu; Michael F Insana
Journal:  J Biomech Eng       Date:  2007-04       Impact factor: 2.097

8.  Blood flow reduction in breast tissue due to mammographic compression.

Authors:  David R Busch; Regine Choe; Turgut Durduran; Daniel H Friedman; Wesley B Baker; Andrew D Maidment; Mark A Rosen; Mitchell D Schnall; Arjun G Yodh
Journal:  Acad Radiol       Date:  2014-02       Impact factor: 3.173

Review 9.  Magnetic resonance elastography (MRE) in cancer: Technique, analysis, and applications.

Authors:  Kay M Pepin; Richard L Ehman; Kiaran P McGee
Journal:  Prog Nucl Magn Reson Spectrosc       Date:  2015-06-23       Impact factor: 9.795

10.  Viscoelasticity imaging using ultrasound: parameters and error analysis.

Authors:  M Sridhar; J Liu; M F Insana
Journal:  Phys Med Biol       Date:  2007-04-10       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.