Flow changes in the aorta associated with the deployment of a AAA stent graft.

P W Walsh1, S Chin-Quee, J E Moore.   

Abstract

The purpose of this study was to investigate the hemodynamic implications of a proximal shift in the aortic bifurcation that results from abdominal aortic aneurysm (AAA) stent graft deployment. A flow model was constructed in which an anatomically accurate model of the aorta was subjected to physiologic pulsatile flow. The model included the celiac, superior mesenteric, left and right renal arteries. The aortic bifurcation, leading to the right and left iliac arteries was included, as well as the lumbar curvature. Flow simulations were performed under resting and mild exercise conditions with and without a Cordis AAA stent graft deployed. Flow patterns were visualized with dye injection and recorded onto video. The flow rates through the iliac and renal arteries were continuously monitored using ultrasonic flowmeters. Flow visualization revealed that flow disturbances at the level of the renal arteries were slightly increased with the deployment of the stent graft. The orientation of the endolegs within the aorta had no perceptible effect on these disturbances. Under mild exercise conditions, very little flow disturbance was observed. In conclusion, there are slight changes in flow disturbance near the renal arteries due to stent graft deployment, but these changes would not be expected to have significant clinical implications.

Entities:  

Mesh:

Year:  2003        PMID: 12649014     DOI: 10.1016/s1350-4533(02)00216-3

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  4 in total

1.  Does lower limb exercise worsen renal artery hemodynamics in patients with abdominal aortic aneurysm?

Authors:  Anqiang Sun; Xiaopeng Tian; Nan Zhang; Zaipin Xu; Xiaoyan Deng; Ming Liu; Xiao Liu
Journal:  PLoS One       Date:  2015-05-06       Impact factor: 3.240

2.  Compliance Study of Endovascular Stent Grafts Incorporated with Polyester and Polyurethane Graft Materials in both Stented and Unstented Zones.

Authors:  Ying Guan; Lu Wang; Jing Lin; Martin W King
Journal:  Materials (Basel)       Date:  2016-08-05       Impact factor: 3.623

3.  Influence of endoleak positions on the pressure shielding ability of stent-graft after endovascular aneurysm repair (EVAR) of abdominal aortic aneurysm (AAA).

Authors:  Jie Li; Xiaopeng Tian; Zhenze Wang; Jiang Xiong; Yubo Fan; Xiaoyan Deng; Anqiang Sun; Xiao Liu
Journal:  Biomed Eng Online       Date:  2016-12-28       Impact factor: 2.819

4.  Effect of a Flared Renal Stent on the Performance of Fenestrated Stent-Grafts at Rest and Exercise Conditions.

Authors:  Harkamaljot Kandail; Mohamad Hamady; Xiao Yun Xu
Journal:  J Endovasc Ther       Date:  2016-05-25       Impact factor: 3.487

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.