Impact of target reproducibility on tumor dose in stereotactic radiotherapy of targets in the lung and liver.

Jörn Wulf1, Ulrich Hädinger, Ulrich Oppitz, Wibke Thiele, Michael Flentje.   

Abstract

BACKGROUND AND
PURPOSE: Previous analyses of target reproducibility in extracranial stereotactic radiotherapy have revealed standard security margins for planning target volume (PTV) definition of 5mm in axial and 5-10mm in longitudinal direction. In this study the reproducibility of the clinical target volume (CTV) of lung and liver tumors within the PTV over the complete course of hypofractionated treatment is evaluated. The impact of target mobility on dose to the CTV is assessed by dose-volume histograms (DVH).
MATERIALS AND METHODS: Twenty-two pulmonary and 21 hepatic targets were treated with three stereotactic fractions of 10 Gy to the PTV-enclosing 100%-isodose with normalization to 150% at the isocenter. A conformal dose distribution was related to the PTV, which was defined by margins of 5-10mm added to the CTV. Prior to each fraction a computed tomography (CT)-simulation over the complete target volume was performed resulting in a total of 60 CT-simulations for lung and 58 CT-simulations for hepatic targets. The CTV from each CT-simulation was segmented and matched with the CT-study used for treatment planning. A DVH of the simulated CTV was calculated for each fraction. The target coverage (TC) of dose to the simulated CTV was defined as the proportion of the CTV receiving at least the reference dose (100%).
RESULTS: A decrease of TC to <95% was found in 3/60 simulations (5%) of pulmonary and 7/58 simulations (12%) of hepatic targets. In two of 22 pulmonary targets (9%) and in four of 21 hepatic targets (19%) a TC of <95% occurred in at least one fraction. At risk for a decreased TC <95% were pulmonary targets with increased breathing mobility and hepatic targets with a CTV exceeding 100 cm(3).
CONCLUSIONS: Target reproducibility was precise within the reference isodose in 91% of lung and 81% of liver tumors with a TC of the complete CTV >or=95% at each fraction of treatment. Pulmonary targets with increased breathing mobility and liver tumors >100 cm(3) are at risk for target deviation exceeding the standard security margins for PTV-definition at least for one fraction and require individual evaluation of sufficient margins.

Entities:  

Mesh:

Year:  2003        PMID: 12648785     DOI: 10.1016/s0167-8140(02)00372-9

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  15 in total

Review 1.  kV cone-beam CT-based IGRT: a clinical review.

Authors:  Judit Boda-Heggemann; Frank Lohr; Frederik Wenz; Michael Flentje; Matthias Guckenberger
Journal:  Strahlenther Onkol       Date:  2011-04-26       Impact factor: 3.621

2.  Safety margin in irradiation of colorectal liver metastases: assessment of the control dose of micrometastases.

Authors:  Max Seidensticker; Peter Wust; Ricarda Rühl; Konrad Mohnike; Maciej Pech; Gero Wieners; Günther Gademann; Jens Ricke
Journal:  Radiat Oncol       Date:  2010-03-24       Impact factor: 3.481

3.  Prescreening based on the presence of CT-scan abnormalities and biomarkers (KL-6 and SP-D) may reduce severe radiation pneumonitis after stereotactic radiotherapy.

Authors:  Hideomi Yamashita; Shino Kobayashi-Shibata; Atsuro Terahara; Kae Okuma; Akihiro Haga; Reiko Wakui; Kuni Ohtomo; Keiichi Nakagawa
Journal:  Radiat Oncol       Date:  2010-05-09       Impact factor: 3.481

Review 4.  Stereotactic body radiotherapy treatment of extracranial metastases.

Authors:  Joseph K Salama; John P Kirkpatrick; Fang-Fang Yin
Journal:  Nat Rev Clin Oncol       Date:  2012-09-25       Impact factor: 66.675

5.  Optimization by visualization of indices.

Authors:  Uwe Haverkamp; Darius Norkus; Jan Kriz; Mariam Müller Minai; Franz-Josef Prott; Hans Theodor Eich
Journal:  Strahlenther Onkol       Date:  2014-06-28       Impact factor: 3.621

6.  In vivo assessment of catheter positioning accuracy and prolonged irradiation time on liver tolerance dose after single-fraction 192Ir high-dose-rate brachytherapy.

Authors:  Lutz Lüdemann; Christian Wybranski; Max Seidensticker; Konrad Mohnike; Siegfried Kropf; Peter Wust; Jens Ricke
Journal:  Radiat Oncol       Date:  2011-09-05       Impact factor: 3.481

7.  Stereotactic, single-dose irradiation of stage I non-small cell lung cancer and lung metastases.

Authors:  Peter Fritz; Hans-Jörg Kraus; Werner Mühlnickel; Udo Hammer; Wolfram Dölken; Walburga Engel-Riedel; Assad Chemaissani; Erich Stoelben
Journal:  Radiat Oncol       Date:  2006-08-20       Impact factor: 3.481

8.  Optimization of extracranial stereotactic radiation therapy of small lung lesions using accurate dose calculation algorithms.

Authors:  Barbara Dobler; Cornelia Walter; Antje Knopf; Daniella Fabri; Rainer Loeschel; Martin Polednik; Frank Schneider; Frederik Wenz; Frank Lohr
Journal:  Radiat Oncol       Date:  2006-11-29       Impact factor: 3.481

9.  Definition of stereotactic body radiotherapy: principles and practice for the treatment of stage I non-small cell lung cancer.

Authors:  M Guckenberger; N Andratschke; H Alheit; R Holy; C Moustakis; U Nestle; O Sauer
Journal:  Strahlenther Onkol       Date:  2013-09-21       Impact factor: 3.621

10.  Feasibility study of automated framework for estimating lung tumor locations for target-based patient positioning in stereotactic body radiotherapy.

Authors:  Satoshi Yoshidome; Hidetaka Arimura; Katsumasa Nakamura; Yoshiyuki Shioyama; Kazushige Atsumi; Yasuhiko Nakamura; Hideki Yoshikawa; Kei Nishikawa; Hideki Hirata
Journal:  Biomed Res Int       Date:  2015-01-05       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.