Literature DB >> 12648012

Piroxicam benzoate--synthesis, HPLC determination, and hydrolysis.

Barend Boneschans1, Anita Wessels, Johan van Staden, Marijana Zovko, Branka Zorc, Jacobus Bergh.   

Abstract

An improved method of piroxicam benzoate synthesis was described, and an isocratic reversed-phase high-performance liquid chromatography method for its determination was developed and fully validated. The method was found to be specific, precise (relative standard deviation 0.3%), accurate (mean recovery 99.9%), and robust. Limit of detection was estimated at 0.055 microg mL(-1) and limit of quantification at 0.185 microg mL(-1). The kinetics of piroxicam benzoate hydrolysis in aqueous buffer solutions (pH 1.1 and 10), simulated gastric and intestinal fluids was studied. The hydrolysis followed first-order kinetics. The following rate constants were obtained at pH 10: k = 1.8 x 10(-3) hr(-1) at 37 degrees C and k = 3.4 x 10(-2) hr(-1) at 60 degrees C. In acidic media, no significant hydrolysis was observed after 24 hr. During the 24-hr period in simulated intestinal fluid, only 10.9% of the starting ester was hydrolyzed.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12648012     DOI: 10.1081/ddc-120016723

Source DB:  PubMed          Journal:  Drug Dev Ind Pharm        ISSN: 0363-9045            Impact factor:   3.225