Literature DB >> 12643636

Polychlorinated biphenyls (PCBs) detection in food samples using an electrochemical immunosensor.

Serena Laschi1, Marcello Mascini, Giampiero Scortichini, Milan Fránek, Marco Mascini.   

Abstract

In this work, a disposable electrochemical immunosensor, based on a competitive assay scheme, was applied to detect polychlorinated biphenyls (PCBs) in food. For this purpose, antibodies against PCBs were directly immobilized onto the carbon surface of a disposable screen-printed electrode. A competition between the PCBs present in the sample and a fixed concentration of an enzyme-labeled PCB was realized and evaluated by electrochemical detection. Alkaline phosphatase was used as the enzyme label, coupled with differential pulse voltammetry (DPV) as the electrochemical technique. The immunosensor was tested on aroclor mixture detection (1242 and 1248) and then on some typologies of food samples to evaluate the possible application for real sample analysis. Samples analyzed were from different matrixes, such as sheep milk, bovine adipose tissue, and bovine muscle. Results obtained were compared with the accredited results according to ISO 17025 methods for PCB detection (HRGC-LRMS) as a confirmatory analysis. Preliminary results show the possibility to use this device as a screening method in food sample analysis. The negligible matrix effect observed may lead to a simplified extraction procedure, and considerable time and consumable savings are the immediate benefits given by the proposed method.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12643636     DOI: 10.1021/jf0208637

Source DB:  PubMed          Journal:  J Agric Food Chem        ISSN: 0021-8561            Impact factor:   5.279


  3 in total

1.  Development of an electrochemical immunoassay for detection of gatifloxacin in swine urine.

Authors:  Jian Yi; Meng Meng; Zhong-qiu Liu; Jin-fang Zhi; Yuan-yang Zhang; Jing Xu; Ya-bin Wang; Jin-ting Liu; Ri-mo Xi
Journal:  J Zhejiang Univ Sci B       Date:  2012-02       Impact factor: 3.066

Review 2.  The need and potential of biosensors to detect dioxins and dioxin-like polychlorinated biphenyls along the milk, eggs and meat food chain.

Authors:  Jeerasak Chobtang; Imke J M de Boer; Ron L A P Hoogenboom; Willem Haasnoot; Aize Kijlstra; Bastiaan G Meerburg
Journal:  Sensors (Basel)       Date:  2011-12-15       Impact factor: 3.576

3.  3A-Amino-3A-Deoxy-(2AS, 3AS)-β-Cyclodextrin Hydrate/Tin Disulfide Modified Screen-Printed Carbon Electrode for the Electrochemical Detection of Polychlorinated Biphenyls.

Authors:  Xinke Liu; Rajalakshmi Sakthivel; Chia-Yin Cheng; Jiangliu Luo; Lijun Song; Jianhua Wu; Wei He; Usman Younis; Ren-Jei Chung
Journal:  Nanoscale Res Lett       Date:  2020-01-03       Impact factor: 4.703

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.