Literature DB >> 12641232

Characterization of an EDTA bonded conducting polymer modified electrode: its application for the simultaneous determination of heavy metal ions.

Md Aminur Rahman1, Mi-Sook Won, Yoon-Bo Shim.   

Abstract

An EDTA bonded conducting polymer modified electrode (EDTA-CPME) was fabricated by polymerization of 3',4'-diamino-2,2';5',2''-terthiophene monomer on a GCE, followed by the reaction with EDTA in the presence of catalyst. The surface of the resulting modified electrode was characterized with EQCM, ESCA, SEM, Auger electron spectroscopy, scanning Auger microscopy, and electrochemical methods. The amounts of polymer and EDTA attached on the polymer film were determined. Simple immersing of the EDTA-CPME into a sample solution led to the chemical deposition through the complexation with Pb2+, Cu2+, and Hg2+ ions, simultaniously. Various experimental parameters that affect the simultaneous analysis of the metal ions, e.g., EDTA amount, pH, deposition time, and deposition temperature, were optimized. Calibration plots for the EDTA-CPME with square wave voltammetry were obtained in the concentration range between 5.0 x 10(-10) and 1.0 x 10(-7) M for Cu(II) and between 7.5 x 10(-10) and 1.0 x 10(-7) M for Pb(II) and Hg(II). The detection limits for Pb(II), Cu(II), and Hg(II) ions were determined to be about 6.0 x 10(-10), 2.0 x 10(-10), and 5.0 x 10(-10) M, respectively. Interference effects from other metal ions were studied at various pHs and it was found that there was little or no effect on the simultaneous determination. The stability of the EDTA-CPME was remarkably improved by coating the surface with the Nafion film, and the electrode can be used for more than one month. Analytical availability of the EDTA-CPME was demonstrated by the application for the certified standard urine reference material and tap water.

Entities:  

Year:  2003        PMID: 12641232     DOI: 10.1021/ac0262917

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  7 in total

1.  Voltammetric Determination of Hg2+, Zn2+, and Pb2+ Ions Using a PEDOT/NTA-Modified Electrode.

Authors:  Jasim M S Alshawi; Mohammed Q Mohammed; Hasan F Alesary; Hani K Ismail; Stephen Barton
Journal:  ACS Omega       Date:  2022-06-01

2.  Tracking metal ions with polypyrrole thin films adhesively bonded to diazonium-modified flexible ITO electrodes.

Authors:  Momath Lo; Abdou K D Diaw; Diariatou Gningue-Sall; Jean-Jacques Aaron; Mehmet A Oturan; Mohamed M Chehimi
Journal:  Environ Sci Pollut Res Int       Date:  2018-05-09       Impact factor: 4.223

Review 3.  Electrochemical Sensors Based on Organic Conjugated Polymers.

Authors:  Md Aminur Rahman; Pankaj Kumar; Deog-Su Park; Yoon-Bo Shim
Journal:  Sensors (Basel)       Date:  2008-01-09       Impact factor: 3.576

Review 4.  Modified electrodes used for electrochemical detection of metal ions in environmental analysis.

Authors:  Gregory March; Tuan Dung Nguyen; Benoit Piro
Journal:  Biosensors (Basel)       Date:  2015-04-29

Review 5.  From Electrochemical Biosensors to Biomimetic Sensors Based on Molecularly Imprinted Polymers in Environmental Determination of Heavy Metals.

Authors:  Cosimino Malitesta; Sabrina Di Masi; Elisabetta Mazzotta
Journal:  Front Chem       Date:  2017-07-06       Impact factor: 5.221

6.  Characterization of urinary concentrations of heavy metals among socioeconomically disadvantaged black pregnant women.

Authors:  Inkyu Han; Kristina W Whitworth; Xueying Zhang; Masoud Afshar; Pamela D Berens; Elaine Symanski
Journal:  Environ Monit Assess       Date:  2020-02-27       Impact factor: 2.513

7.  Isothermal Kinetics of Poly(butylene adipate-co-butylene itaconate) Copolyesters with Ethylenediaminetetraacetic Acid.

Authors:  Chin-Wen Chen; Te-Sheng Hsu; Syang-Peng Rwei
Journal:  ACS Omega       Date:  2020-02-06
  7 in total