Literature DB >> 12639038

Evaluation of Bacillus subtilis and coliphage MS2 as indicators of advanced water treatment efficiency.

A Huertas1, B Barbeau, C Desjardins, A Galarza, M A Figueroa, G A Toranzos.   

Abstract

The assessment of water treatment facilities for their efficiency using alternate indicators is of paramount importance. Current methods for assessing efficiency are limited by the specific characteristics of the microorganisms, such as their different sensitivities to disinfectants. A pilot study was carried out to compare different treatment scenarios for the future upgrade of the Sergio Cuevas Water Treatment plant (the largest in the Caribbean) in San Juan, Puerto Rico. The treatment units under investigation included a coagulation-flocculation-sedimentation unit, dual-media filters, micro-filtration units, intermediate ozone injection and contact columns as well as a biological filtration unit. The plant was challenged at different stages of treatment with Bacillus subtilis spores and MS2 coliphages in an attempt to test them as possible alternate indicators of treatment plant performance. These organisms were chosen because of their resistance to disinfection and desiccation, their low analysis costs and ease of detection. The removal of spores and coliphages by each treatment unit tested was calculated by seeding a known concentration (5-7 log10) of spores and coliphages and following the removal or disinfection rates. The seeded indicators were detected using traditional culture techniques. Ballasted clarification was shown to be highly efficient at removing 99.1% (approximately 3 log10) of the spores and 85.1% (approximately 0.86 log10) of MS2. Ozone treatment inactivated 80.37% (approximately 1.4 log10) spores and 99.95% (approximately 3.07 log10) coliphages. The coliphage inactivation rate obtained confirmed data obtained by previous studies indicating that MS2 was less resistant to ozonation than B subtilis spores. The membrane technology had the best efficiency in terms of physical removal of spores achieving over 99.9% (> 3 log10) removal. Coliphage removal mechanisms remain to be determined and will be a future focus of the study. Preliminary results indicate that aerobic spores and coliphages may be useful as indicators to determine the efficiency of different drinking water treatment technologies.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12639038

Source DB:  PubMed          Journal:  Water Sci Technol        ISSN: 0273-1223            Impact factor:   1.915


  4 in total

1.  On the use of total aerobic spore bacteria to make treatment decisions due to Cryptosporidium risk at public water system wells.

Authors:  Philip Berger; Michael J Messner; Jake Crosby; Deborah Vacs Renwick; Austin Heinrich
Journal:  Int J Hyg Environ Health       Date:  2018-03-08       Impact factor: 5.840

2.  Real-time fluorogenic reverse transcription-PCR assays for detection of bacteriophage MS2.

Authors:  Kevin P O'Connell; Jennifer R Bucher; Patricia E Anderson; Cheng J Cao; Akbar S Khan; Mark V Gostomski; James J Valdes
Journal:  Appl Environ Microbiol       Date:  2006-01       Impact factor: 4.792

3.  Bactericidal effect of solar water disinfection under real sunlight conditions.

Authors:  M Boyle; C Sichel; P Fernández-Ibáñez; G B Arias-Quiroz; M Iriarte-Puña; A Mercado; E Ubomba-Jaswa; K G McGuigan
Journal:  Appl Environ Microbiol       Date:  2008-03-21       Impact factor: 4.792

4.  Antibacterial performance of polymer quaternary ammonium salt-capped silver nanoparticles on Bacillus subtilis in water.

Authors:  Jingyu Wang; Minghao Sui; Zhanfang Ma; Hongwei Li; Bojie Yuan
Journal:  RSC Adv       Date:  2019-08-15       Impact factor: 3.361

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.