Literature DB >> 12638057

Simultaneous determination of 2-nitrophenol and 4-nitrophenol based on the multi-wall carbon nanotubes Nafion-modified electrode.

Wensheng Huang1, Chunhai Yang, Shenghui Zhang.   

Abstract

In this work, multi-wall carbon nanotubes (MWNT) were conveniently dispersed into Nafion-ethanol solution, and the MWNT-Nafion-modified glassy carbon electrode (GCE) was described for the simultaneous determination of 2-nitrophenol and 4-nitrophenol. At pH 4.0 phosphate buffer, the reduction peak currents of 2-nitrophenol (at -0.8 V) and 4-nitrophenol (at -1.0 V) increase significantly at the MWNT-Nafion-modified GCE, in comparison with that at the Nafion-modified GCE and the bare GCE. The experimental parameters, such as solution pH of phosphate buffer, accumulation potential and time, and the amounts of MWNT-Nafion onto the GCE surface, were optimized. The reduction peak currents are linear with the concentration of 2-nitrophenol from 5 x 10(-8) to 1 x 10(-5) mol L(-1) and with that of 4-nitrophenol from 1 x 10(-7) to 1 x 10(-5) mol L(-1). The detection limits after 3-min accumulation are 1 x 10(-8) mol L(-1) for 2-nitrophenol and for 4 x 10(-8) mol L(-1) for 4-nitrophenol. This modified electrode was applied to direct determination of 2-nitrophenol and 4-nitrophenol in lake water samples.

Entities:  

Year:  2003        PMID: 12638057     DOI: 10.1007/s00216-002-1745-5

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  5 in total

1.  Simultaneous polarographic determination of 2-nitrophenol and 4-nitrophenol by differential pulse polarography method and support vector regression.

Authors:  Karim Asadpour-Zeynali; Payam Soheili-Azad
Journal:  Environ Monit Assess       Date:  2011-04-12       Impact factor: 2.513

2.  Voltammetric determination of 4-nitrophenol using a glassy carbon electrode modified with a gold-ZnO-SiO2 nanostructure.

Authors:  Arash Jalili Ghazizadeh; Abbas Afkhami; Hasan Bagheri
Journal:  Mikrochim Acta       Date:  2018-05-11       Impact factor: 5.833

3.  The Application of Nafion Metal Catalyst Free Carbon Nanotube Modified Gold Electrode: Voltammetric Zinc Detection in Serum.

Authors:  Wei Yue; Adam Bange; Bill L Riehl; Jay M Johnson; Ian Papautsky; William R Heineman
Journal:  Electroanalysis       Date:  2013-10       Impact factor: 3.223

4.  Performance of graphene-zinc oxide nanocomposite coated-glassy carbon electrode in the sensitive determination of para-nitrophenol.

Authors:  Riyaz Ahmad Dar; Gowhar Ahmad Naikoo; Ashwini Kumar Srivastava; Israr Ul Hassan; Shashi P Karna; Lily Giri; Ahamad M H Shaikh; Mashallah Rezakazemi; Waqar Ahmed
Journal:  Sci Rep       Date:  2022-01-07       Impact factor: 4.379

5.  Novel construction of carbon nanofiber/CuCrO2 composite for selective determination of 4-nitrophenol in environmental samples and for supercapacitor application.

Authors:  Subramanian Sakthinathan; Ramachandran Rajakumaran; Arjunan Karthi Keyan; Chung-Lun Yu; Chia-Fang Wu; Sivaramakrishnan Vinothini; Shen-Ming Chen; Te-Wei Chiu
Journal:  RSC Adv       Date:  2021-04-28       Impact factor: 3.361

  5 in total