Tissue adhesion to bioactive glass-coated silicone tubing in a rat model of peritoneal dialysis catheters and catheter tunnels.

Edward A Ross1, Christopher D Batich, William L Clapp, Judith E Sallustio, Nadeen C Lee.   

Abstract

BACKGROUND: Silicone peritoneal dialysis catheters do not develop tissue ingrowth, lack a mechanical barrier to periluminal bacterial migration and need cuffs for anchorage. We hypothesized that a bioactive glass coating composed of silicon, calcium, sodium and phosphorous oxides would cause a beneficial tissue reaction causing catheter adhesion, and tested this in a rat model.
METHODS: A hexane solvent-based method of coating silicone tubes with Bioglass powder was used, which maintained flexibility, and then the ultrastructure was confirmed with scanning electron microscopy (EM). Segments 2.5 cm were implanted subcutaneously in 8 Sprague-Dawley rats, with uncoated tubes as a contralateral control, and histology was done at 2, 4 and 6 weeks, including special stains and EM.
RESULTS: The uncoated segments grossly had no adherence to surrounding tissue, and were physically separate from a thin fibrous capsule of approximately 50 micro width. Trichrome stains demonstrated the capsule was rich in collagen. There was minimal adjacent tissue reaction. In contrast, the coated tubes were palpably fixed to the soft tissues, and sections demonstrated an adjacent prominent layer of macrophages and multinucleated giant cells. Small numbers of lymphocytes were noted. This cellular reaction increased over the 6-week implant duration, and was also associated with neovascularization of the tissue adjacent to the segments (33 vessels in coated vs. 20 in controls per x 200 field, P < 0.0001). Many refractile silicone particles and prominent multinucleated giant cells were present, with small numbers of lymphocytes and macrophages. Stains showed scattered discontinuous calcific deposits. These findings are consistent with reports that the Bioglass(R) silicon oxide leads to the formation of a layer of hydroxyapatite, which binds to collagen and induces a tissue cellular reaction.
CONCLUSIONS: In summary, bioactive glass coatings can improve the tissue retention of silicone tubing by promoting adhesion by collagen and cell proliferation, and are promising for future studies of peritoneal dialysis catheters.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12631137     DOI: 10.1046/j.1523-1755.2003.00764.x

Source DB:  PubMed          Journal:  Kidney Int        ISSN: 0085-2538            Impact factor:   10.612


  4 in total

1.  45S5-Bioglass(®)-based 3D-scaffolds seeded with human adipose tissue-derived stem cells induce in vivo vascularization in the CAM angiogenesis assay.

Authors:  Marina Handel; Timo R Hammer; Patcharakamon Nooeaid; Aldo R Boccaccini; Dirk Hoefer
Journal:  Tissue Eng Part A       Date:  2013-08-12       Impact factor: 3.845

2.  Preliminary Evaluation of the Viability of Peritoneal Drainage Catheters Implanted in Rats for Extended Durations.

Authors:  Nathan Legband; Arielle Black; Craig Kreikemeier-Bower; Benjamin S Terry
Journal:  J Invest Surg       Date:  2018-01-18       Impact factor: 2.533

Review 3.  Experimental models in peritoneal dialysis (Review).

Authors:  Bo Yang; Mengmeng Wang; Xue Tong; Ghada Ankawi; Lin Sun; Hongtao Yang
Journal:  Exp Ther Med       Date:  2021-01-21       Impact factor: 2.447

Review 4.  Bioactive Glass and Glass-Ceramic Scaffolds for Bone Tissue Engineering.

Authors:  Lutz-Christian Gerhardt; Aldo R Boccaccini
Journal:  Materials (Basel)       Date:  2010-07-06       Impact factor: 3.623

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.