Literature DB >> 12630832

Kalman filtering for adaptive nonuniformity correction in infrared focal-plane arrays.

Sergio N Torres1, Majeed M Hayat.   

Abstract

A novel statistical approach is undertaken for the adaptive estimation of the gain and bias nonuniformity in infrared focal-plane array sensors from scene data. The gain and the bias of each detector are regarded as random state variables modeled by a discrete-time Gauss-Markov process. The proposed Gauss-Markov framework provides a mechanism for capturing the slow and random drift in the fixed-pattern noise as the operational conditions of the sensor vary in time. With a temporal stochastic model for each detector's gain and bias at hand, a Kalman filter is derived that uses scene data, comprising the detector's readout values sampled over a short period of time, to optimally update the detector's gain and bias estimates as these parameters drift. The proposed technique relies on a certain spatiotemporal diversity condition in the data, which is satisfied when all detectors see approximately the same range of temperatures within the periods between successive estimation epochs. The performance of the proposed technique is thoroughly studied, and its utility in mitigating fixed-pattern noise is demonstrated with both real infrared and simulated imagery.

Year:  2003        PMID: 12630832     DOI: 10.1364/josaa.20.000470

Source DB:  PubMed          Journal:  J Opt Soc Am A Opt Image Sci Vis        ISSN: 1084-7529            Impact factor:   2.129


  4 in total

1.  Robust Approach for Nonuniformity Correction in Infrared Focal Plane Array.

Authors:  Ayoub Boutemedjet; Chenwei Deng; Baojun Zhao
Journal:  Sensors (Basel)       Date:  2016-11-10       Impact factor: 3.576

2.  A Median-Ratio Scene-Based Non-Uniformity Correction Method for Airborne Infrared Point Target Detection System.

Authors:  Shuai Ding; Dejiang Wang; Tao Zhang
Journal:  Sensors (Basel)       Date:  2020-06-08       Impact factor: 3.576

3.  Modeling and Compensating Temperature-Dependent Non-Uniformity Noise in IR Microbolometer Cameras.

Authors:  Alejandro Wolf; Jorge E Pezoa; Miguel Figueroa
Journal:  Sensors (Basel)       Date:  2016-07-19       Impact factor: 3.576

4.  Infrared light field imaging system free of fixed-pattern noise.

Authors:  Pablo A Coelho; Jorge E Tapia; Francisco Pérez; Sergio N Torres; Carlos Saavedra
Journal:  Sci Rep       Date:  2017-10-12       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.