Literature DB >> 12628430

In vitro corrosion behavior of bioceramic, metallic, and bioceramic-metallic coated stainless steel dental implants.

M H Fathi1, M Salehi, A Saatchi, V Mortazavi, S B Moosavi.   

Abstract

OBJECTIVES: The most common metals and alloys used in dentistry may be exposed to a process of corrosion in vivo that make them cytotoxic. The biocompatibility of dental alloys is primarily related to their corrosion behavior. The aim of this work was to evaluate the corrosion behavior and thus the biocompatibility of the uncoated and coated stainless steels and compare the effect of type of coatings on corrosion behavior.
METHODS: Three types of coatings, hydroxyapatite (HA), titanium (Ti), and a double-layer HA/Ti on AISI 316L stainless steel were made. HA coating was produced using plasma-spraying technique and Ti coating was made using physical vapor deposition process. In order to perform a novel double-layer composite coating, a top layer of HA was plasma-sprayed over a physical vapor deposited Ti layer on AISI 316L stainless steel. Structural characterization techniques including XRD, SEM and EDX were used to investigate the microstructure, morphology and crystallinity of the coatings. Electrochemical potentiodynamic tests were performed in physiological solutions in order to determine and compare the corrosion behavior of the coated and uncoated specimens as an indication of biocompatibility.
RESULTS: Double-layer HA/Ti coating on AISI 316L SS had a positive effect on improvement of corrosion behavior. The decrease in corrosion current densities was significant for these coated specimens and was much lower than the values obtained for uncoated and single HA coated specimens. Ti coating on AISI 316L SS also has a beneficial effect on corrosion behavior. The results were compared with the results of corrosion behavior of HA coated commercially pure titanium (cpTi) and uncoated cpTi. SIGNIFICANCE: These results demonstrated that the double-layer HA/Ti coated 316L SS can be used as an endodontic implant and two goals including improvement of corrosion resistance and bone osteointegration can be obtained simultaneously.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12628430     DOI: 10.1016/s0109-5641(02)00029-5

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  13 in total

Review 1.  Tissue Engineering and Regenerative Medicine in Iran: Current State of Research and Future Outlook.

Authors:  Sahba Mobini; Manijeh Khanmohammadi; Hamed Heidari-Vala; Ali Samadikuchaksaraei; Ali Moshiri; Somaieh Kazemnejad
Journal:  Mol Biotechnol       Date:  2015-07       Impact factor: 2.695

2.  Novel nanocomposite coating for dental implant applications in vitro and in vivo evaluation.

Authors:  M Mehdikhani-Nahrkhalaji; M H Fathi; V Mortazavi; S B Mousavi; B Hashemi-Beni; S M Razavi
Journal:  J Mater Sci Mater Med       Date:  2011-11-30       Impact factor: 3.896

Review 3.  Corrosion degradation and prevention by surface modification of biometallic materials.

Authors:  Raghuvir Singh; Narendra B Dahotre
Journal:  J Mater Sci Mater Med       Date:  2006-12-02       Impact factor: 4.727

4.  Novel bioactive Co-based alloy/FA nanocomposite for dental applications.

Authors:  Mohammadhossein Fathi; Mehdi Ahmadian; Mojgan Bahrami
Journal:  Dent Res J (Isfahan)       Date:  2012-03

5.  Molecular plasma deposition: biologically inspired nanohydroxyapatite coatings on anodized nanotubular titanium for improving osteoblast density.

Authors:  Ganesan Balasundaram; Daniel M Storey; Thomas J Webster
Journal:  Int J Nanomedicine       Date:  2015-01-12

Review 6.  The Role of Oral Cavity Biofilm on Metallic Biomaterial Surface Destruction-Corrosion and Friction Aspects.

Authors:  Joanna Mystkowska; Katarzyna Niemirowicz-Laskowska; Dawid Łysik; Grażyna Tokajuk; Jan R Dąbrowski; Robert Bucki
Journal:  Int J Mol Sci       Date:  2018-03-06       Impact factor: 5.923

7.  Enhancement of osteoblast activity on nanostructured NiTi/hydroxyapatite coatings on additive manufactured NiTi metal implants by nanosecond pulsed laser sintering.

Authors:  Biwei Deng; Angela Bruzzaniti; Gary J Cheng
Journal:  Int J Nanomedicine       Date:  2018-11-30

8.  Potential Causes of Titanium Particle and Ion Release in Implant Dentistry: A Systematic Review.

Authors:  Rafael Delgado-Ruiz; Georgios Romanos
Journal:  Int J Mol Sci       Date:  2018-11-13       Impact factor: 5.923

9.  Influence of the electrolyte's pH on the properties of electrochemically deposited hydroxyapatite coating on additively manufactured Ti64 alloy.

Authors:  Alina Vladescu; Diana M Vranceanu; Slawek Kulesza; Alexey N Ivanov; Mirosław Bramowicz; Alexander S Fedonnikov; Mariana Braic; Igor A Norkin; Andrey Koptyug; Maria O Kurtukova; Mihaela Dinu; Iulian Pana; Maria A Surmeneva; Roman A Surmenev; Cosmin M Cotrut
Journal:  Sci Rep       Date:  2017-12-01       Impact factor: 4.379

10.  Optimization of mechanical properties, biocorrosion properties and antibacterial properties of wrought Ti-3Cu alloy by heat treatment.

Authors:  Mianmian Bao; Ying Liu; Xiaoyan Wang; Lei Yang; Shengyi Li; Jing Ren; Gaowu Qin; Erlin Zhang
Journal:  Bioact Mater       Date:  2018-02-03
View more