Literature DB >> 12625866

Characterisation and evaluation of novel surfactant bacterial anti-adherent coatings for endotracheal tubes designed for the prevention of ventilator-associated pneumonia.

David S Jones1, Shauna McMeel, Colin G Adair, Sean P Gorman.   

Abstract

It is accepted that ventilator-associated pneumonia is a frequent cause of morbidity and mortality in intensive care patients. This study describes the physicochemical properties of novel surfactant coatings of the endotracheal tube and the resistance to microbial adherence of surfactant coated endotracheal tube polyvinylchloride (PVC). Organic solutions of surfactants containing a range of ratios of cholesterol and lecithin (0:100, 25:75, 50:50, 75:25, dissolved in dichloromethane) were prepared and coated onto endotracheal tube PVC using a multiple dip-coating process. Using modulated temperature differential scanning calorimetry it was confirmed that the binary surfactant systems existed as physical mixtures. The surface properties of both surfactant-coated and uncoated PVC, following treatment with either pooled human saliva or phosphate-buffered saline (PBS), were characterised using dynamic contact angle analysis. Following treatment with saliva, the contact angles of PVC decreased; however, those of the coated biomaterials were unaffected, indicating different rates and extents of macromolecular adsorption from saliva onto the coated and uncoated PVC. The advancing and receding contact angles of the surfactant-coated PVC were unaffected by sonication, thereby providing evidence of the durability of the coatings. The cell surface hydrophobicity and zeta potentials of isolates of Staphylococcus aureus and Pseudomonas aeruginosa, following treatment with either saliva or PBS, and their adherence to uncoated and surfactant-coated PVC (that had been pre-treated with saliva) were examined. Adherence of S. aureus and Ps. aeruginosa to surfactant-coated PVC at each successive time period (0.5, 1, 2, 4, 8 h) was significantly lower than to uncoated PVC, the extent of the reduction frequently exceeding 90%. Interestingly, the microbial anti-adherent properties of the coatings were dependent on the lecithin content. Based on the impressive microbial anti-adherence properties and durability of the surfactant coating on PVC following dip coatings, it is proposed that these systems may usefully reduce the incidence of ventilator-associated pneumonia when employed as luminal coatings of the endotracheal tube.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12625866     DOI: 10.1111/j.2042-7158.2003.tb02432.x

Source DB:  PubMed          Journal:  J Pharm Pharmacol        ISSN: 0022-3573            Impact factor:   3.765


  5 in total

Review 1.  Pseudomonas aeruginosa, Candida albicans, and device-related nosocomial infections: implications, trends, and potential approaches for control.

Authors:  George E Pierce
Journal:  J Ind Microbiol Biotechnol       Date:  2005-05-03       Impact factor: 3.346

2.  Antimicrobial-coated endotracheal tubes: an experimental study.

Authors:  Lorenzo Berra; Francesco Curto; Gianluigi Li Bassi; Patrice Laquerriere; Betsey Pitts; Andrea Baccarelli; Theodor Kolobow
Journal:  Intensive Care Med       Date:  2008-04-17       Impact factor: 17.440

Review 3.  Silver-coated endotracheal tubes for prevention of ventilator-associated pneumonia in critically ill patients.

Authors:  George Tokmaji; Hester Vermeulen; Marcella C A Müller; Paulus H S Kwakman; Marcus J Schultz; Sebastian A J Zaat
Journal:  Cochrane Database Syst Rev       Date:  2015-08-12

4.  Antimicrobial biocides in the healthcare environment: efficacy, usage, policies, and perceived problems.

Authors:  Jean-Yves Maillard
Journal:  Ther Clin Risk Manag       Date:  2005-12       Impact factor: 2.423

5.  Gnotobiotic Human Colon Ex Vivo.

Authors:  Frank D McDermott; David M A Folan; Des C Winter; Michael A Folan; Alan W Baird
Journal:  Gastroenterology Res       Date:  2015-10-21
  5 in total