Abstract

The present Review describes the progress made in using imaging optical fiber bundles for fluorescence and electrochemical-initiated chemiluminescence imaging. A novel optoelectrochemical micro-ring array has been fabricated and demonstrated for concurrent electrochemical and optical measurements. The device comprises optical fibers coated with gold via electroless gold deposition and assembled in a random array format. The design yielded an array of approximately 200 micro-ring electrodes, where interdiffusional problems were minimized. The inner diameter of the ring electrode is fixed by the diameter of the individual optical fibers (25 microns), while the outer radius is determined by the thickness of the deposited gold. While all the fibers are optically addressable, they are not all electrochemically addressable. The resolution of this device is in the tens of micrometers range, determined by the diameter of the optical fiber (25 microns) and by the spacing between each electrically connected fiber. For the purpose of having well-behaved microelectrode characteristics, this spacing was designed to be larger than 60 microns. The array was characterized using ferrocyanide in aqueous solution as a model electroactive species to demonstrate that this microelectrode array format exhibits steady-state currents at short response times. This device has potential application to be used as an optoelectronic sensor, especially for the electrolytic generation and transmission of electrochemiluminescence, and was used to demonstrate that electrochemically generated luminescent products can be detected with the fiber assembly.

Entities:  

Mesh:

Year:  2003        PMID: 12619418     DOI: 10.1002/cphc.200390029

Source DB:  PubMed          Journal:  Chemphyschem        ISSN: 1439-4235            Impact factor:   3.102


  5 in total

1.  Gold coated optical fibers as three-dimensional electrodes for microfluidic enzymatic biofuel cells: Toward geometrically enhanced performance.

Authors:  Denis Desmaële; Louis Renaud; Sophie Tingry
Journal:  Biomicrofluidics       Date:  2015-08-18       Impact factor: 2.800

2.  Carbon-ring microelectrode arrays for electrochemical imaging of single cell exocytosis: fabrication and characterization.

Authors:  Yuqing Lin; Raphaël Trouillon; Maria I Svensson; Jacqueline D Keighron; Ann-Sofie Cans; Andrew G Ewing
Journal:  Anal Chem       Date:  2012-03-06       Impact factor: 6.986

3.  Combining scanning electrochemical microscopy with infrared attenuated total reflection spectroscopy for in situ studies of electrochemically induced processes.

Authors:  Liqun Wang; Janusz Kowalik; Boris Mizaikoff; Christine Kranz
Journal:  Anal Chem       Date:  2010-04-15       Impact factor: 6.986

4.  Monitoring scanning electrochemical microscopy approach curves with mid-infrared spectroscopy: toward a novel current-independent positioning mode.

Authors:  Liqun Wang; Christine Kranz; Boris Mizaikoff
Journal:  Anal Chem       Date:  2010-04-15       Impact factor: 6.986

5.  Applications and advances in electronic-nose technologies.

Authors:  Alphus D Wilson; Manuela Baietto
Journal:  Sensors (Basel)       Date:  2009-06-29       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.