Literature DB >> 12619263

Identification of occlusal sealants using optical coherence tomography.

Linda L Otis1, Raed I al-Sadhan, Jonathan Meiers, Deborah Redford-Badwal.   

Abstract

OBJECTIVE: Optical coherence tomography (OCT) is a new imaging technique that uses light to image dental structures interferometrically. OCT creates cross-sectional images that have potential diagnostic value for dental applications. When used in epidemiological studies, OCT offers a safe, non-invasive technique to discriminate occlusal sealants and composite restorations. This paper summarizes a study in which dentists were asked to interpret and discriminate between OCT images.
METHODOLOGY: Twenty-one dentists were asked to interpret OCT images of nine extracted premolars that were either not restored, contained an occlusal sealant or were restored with a composite restoration.
RESULTS: Although the dentists were previously unfamiliar with OCT images, they adapted well and felt confident in their diagnoses using this new technology. The sensitivity of OCT to discriminate composite and sealants was > 0.92, while the specificity of discrimination was > 0.94. The capacity of OCT to discriminate sealants from non-restored occlusal surfaces was slightly less (sensitivity 0.88; specificity 0.86), but still within a clinically acceptable level. Inter- and intra-rater reliability, as measured by the kappa statistic, also revealed excellent performance by dentists using this new imaging technology. Intra-rater reliability was very good, ranging from 0.82 to 1.0. Inter-rater reliability was also high, predominately in the "Good" to "Very Good" agreement range.
CONCLUSION: This preliminary study indicates OCT imaging may be an important new technology for discriminating occlusal sealants and composite restorations.

Mesh:

Substances:

Year:  2003        PMID: 12619263

Source DB:  PubMed          Journal:  J Clin Dent        ISSN: 0895-8831


  11 in total

1.  Influence of dental resin material composition on cross-polarization-optical coherence tomography imaging.

Authors:  Carmen Lammeier; YuPing Li; Scott Lunos; Alex Fok; Joel Rudney; Robert S Jones
Journal:  J Biomed Opt       Date:  2012-10       Impact factor: 3.170

2.  Near-infrared imaging of demineralization under sealants.

Authors:  Henry Tom; Jacob C Simon; Kenneth H Chan; Cynthia L Darling; Daniel Fried
Journal:  J Biomed Opt       Date:  2014       Impact factor: 3.170

3.  Ability of optical coherence tomography to detect caries beneath commonly used dental sealants.

Authors:  Jennifer S Holtzman; Kathryn Osann; Jessica Pharar; Kenneth Lee; Yeh-Chan Ahn; Travis Tucker; Sharareh Sabet; Zhongping Chen; Ripsik Gukasyan; Petra Wilder-Smith
Journal:  Lasers Surg Med       Date:  2010-10       Impact factor: 4.025

4.  Imaging Simulated Secondary Caries Lesions with Cross Polarization OCT.

Authors:  Jonathan Stahl; Hobin Kang; Daniel Fried
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2010-03-05

Review 5.  Low-Shrinkage Resin Matrices in Restorative Dentistry-Narrative Review.

Authors:  Ebtehal G Albeshir; Rashed Alsahafi; Reem Albluwi; Abdulrahman A Balhaddad; Heba Mitwalli; Thomas W Oates; Gary D Hack; Jirun Sun; Michael D Weir; Hockin H K Xu
Journal:  Materials (Basel)       Date:  2022-04-18       Impact factor: 3.748

6.  Near-IR imaging of demineralization under sealants.

Authors:  Henry Tom; Kenneth H Chan; Cynthia L Darling; Daniel Fried
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2014-02-18

Review 7.  Optical techniques for the noninvasive diagnosis of skin cancer.

Authors:  Mihaela Antonina Calin; Sorin Viorel Parasca; Roxana Savastru; Marian Romeo Calin; Simona Dontu
Journal:  J Cancer Res Clin Oncol       Date:  2013-04-04       Impact factor: 4.553

8.  Optical tecnology developments in biomedicine: history, current and future.

Authors:  Shoko Nioka; Yu Chen
Journal:  Transl Med UniSa       Date:  2011-10-17

Review 9.  Clinical applications of optical coherence tomography in urology.

Authors:  Hsing-Wen Wang; Yu Chen
Journal:  Intravital       Date:  2014-04-30

Review 10.  The Use of Optical Coherence Tomography in Dental Diagnostics: A State-of-the-Art Review.

Authors:  Monika Machoy; Julia Seeliger; Liliana Szyszka-Sommerfeld; Robert Koprowski; Tomasz Gedrange; Krzysztof Woźniak
Journal:  J Healthc Eng       Date:  2017-07-16       Impact factor: 2.682

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.