Susanne Picard1, Lennart Robertsson, Long-Sheng Ma, Kaj Nyholm, Mikko Merimaa, Tero E Ahola, Petr Balling, Petr Kren, Jean-Pierre Wallerand.
Abstract
A frequency comparison was carried out between iodine-stabilized Nd:YAG lasers at 532 nm from the Bureau International des Poids et Mesures, the Centre for Metrology and Accreditation, the Czech Metrology Institute, and the Bureau National de Métrologie-Institut National de Métrologie. The frequency differences between lasers, as well as the frequency reproducibility of each system,were investigated. Pressure-, modulation-, and power-induced shifts were studied. A frequency dispersion (1 sigma) of 3.5 kHz (6.2 x 10(-12) in relative terms) with an average reproducibility for each laser of the order of 0.4 kHz (7.1 x 10(-13) in relative terms) was observed over the duration of the comparison. Relative stabilities better than 1 x 10(13) at 1 s were demonstrated for the third-harmonic systems.Entities:
Year: 2003 PMID: 12617219 DOI: 10.1364/ao.42.001019
Source DB: PubMed Journal: Appl Opt ISSN: 1559-128X Impact factor: 1.980