Literature DB >> 12616354

Treatment of type III endoleak with an aortouniiliac stent graft.

Theodore H Teruya1, Juan Ayerdi, Maurice M Solis, Ahmed M Abou-Zamzam, Jeffrey L Ballard, Robert B McLafferty, Kim J Hodgson.   

Abstract

The purpose of this study was to present a novel treatment method for repair of a type III endoleak due to separation of modular components of an AneuRx (Medtronic AVE, Sunnyvalle, CA) stent graft as a result of graft kinking. A 73-year-old male had undergone endovascular repair of a 8.2-cm abdominal aortic aneurysm (AAA) 2 years previously. An aortic extender cuff was required to secure the proximal graft. Computed tomographic (CT) follow-up revealed a type III endoleak at 6-month follow-up. Plain radiographs showed separation between the main graft body and the aortic extender cuff. A second custom-made 28 mm x 5.5 cm aortic extender cuff was placed to seal the type III endoleak. Follow-up CT showed a persistent endoleak with an increase in AAA size to 10.5 cm. The patient underwent remedial AAA repair with an aortouniiliac endograft placed within the previous stent graft and a femorofemoral bypass. At 3-month follow-up there was no detectable endoleak. This constitutes an alternative endovascular therapy for modular device separation (type-III endoleak) after endoluminal AAA repair in patients who cannot undergo repair with a second bifurcated graft.

Entities:  

Mesh:

Year:  2003        PMID: 12616354     DOI: 10.1007/s10016-001-0395-y

Source DB:  PubMed          Journal:  Ann Vasc Surg        ISSN: 0890-5096            Impact factor:   1.466


  4 in total

1.  Renewed endovascular repair for recurrent acute abdominal aortic aneurysm.

Authors:  Umberto M Bracale; Clark J Zeebregts; Ben R Saleem; Ted R Prins; Eric L G Verhoeven
Journal:  Emerg Radiol       Date:  2008-05-15

2.  Delayed Type IIIb endoleak secondary to graft fabric tear 7 years following implantation of a Medtronic Talent endovascular aortic device: A case report and review of the literature.

Authors:  Vinay Kansal; Sudhir Nagpal
Journal:  SAGE Open Med Case Rep       Date:  2016-09-20

3.  Type III Endoleak of a Disconnected Stent-graft Limb.

Authors:  Yusuke Ochiumi; Yoriyasu Suzuki; Yasuhiro Oba
Journal:  Intern Med       Date:  2017-08-21       Impact factor: 1.271

4.  Type III Endoleak Leading to Aortic Rupture After Endovascular Repair.

Authors:  Yahia Suliemeh; Mahmoud Bouabane; Mohammad Deershamarkha; Adnan Benzirar; Omar El Mahi
Journal:  Cureus       Date:  2022-07-15
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.