Literature DB >> 12616021

Benign breast lesions: minimally invasive vacuum-assisted biopsy with 11-gauge needles patient acceptance and effect on follow-up imaging findings.

Sabine Huber1, Monika Wagner, Michael Medl, Heinrich Czembirek.   

Abstract

PURPOSE: To evaluate patient acceptance of stereotactic or ultrasonographically (US) guided directional vacuum-assisted 11-gauge needle biopsy of breast lesions and short- and long-term changes at mammography and US resulting from the procedure.
MATERIALS AND METHODS: For 91 benign lesions that had been sampled at either stereotactic or US-guided directional vacuum-assisted breast biopsy performed with 11-gauge needles, clinical, mammographic, and US changes were evaluated 1 week after biopsy; 6-month follow-up findings were available for 74 lesions. The subjective outcome of the procedure and patient satisfaction were assessed on the basis of a patient-completed questionnaire that incorporated a multistage scoring system. Statistical analysis of scores for condition for both biopsy methods was performed with the chi2 test.
RESULTS: Adverse events occurred during the procedure in four patients. Clinically visible hematomas were observed at 1-week follow-up in 79% of patients. Densities were observed on mammograms in 46% of patients 1 week after biopsy; hematomas with a maximum diameter of 2 cm were seen on sonograms in 74%. Six months after biopsy, mammography revealed discrete architectural changes in one case. No abnormalities were found at 6-month follow-up US. Fifteen patients had various complaints during the procedure; six reported feeling constrained during the first few days after biopsy, and one patient was not satisfied with the cosmetic result. No patient reported a retrospective preference for surgical biopsy instead of directional vacuum-assisted biopsy. Analysis of scores for the stereotactic and US-guided methods revealed a significant difference (P <.001) in favor of the stereotactic method for condition during biopsy, while scores for condition in the first days after biopsy were more equally distributed between the two methods (P =.386).
CONCLUSION: Directional vacuum-assisted 11-gauge needle biopsy of the breast is well accepted by patients and rarely produces changes that may alter the mammographic or sonographic appearance of the breast at 6-month follow-up.

Entities:  

Mesh:

Year:  2003        PMID: 12616021     DOI: 10.1148/radiol.2271011933

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  9 in total

Review 1.  Accuracy of ultrasound-guided, large-core needle breast biopsy.

Authors:  G Schueller; C Schueller-Weidekamm; T H Helbich
Journal:  Eur Radiol       Date:  2008-04-15       Impact factor: 5.315

2.  A variable stiffness mechanism for steerable percutaneous instruments: integration in a needle.

Authors:  Iris De Falco; Costanza Culmone; Arianna Menciassi; Jenny Dankelman; John J van den Dobbelsteen
Journal:  Med Biol Eng Comput       Date:  2018-06-04       Impact factor: 2.602

3.  Ultrasound-guided vacuum-assisted breast biopsy: Use at the European Institute of Oncology in 2010.

Authors:  F Abbate; E Cassano; S Menna; G Viale
Journal:  J Ultrasound       Date:  2011-10-21

Review 4.  The B3 conundrum-the radiologists' perspective.

Authors:  Nisha Sharma; Louise S Wilkinson; Sarah E Pinder
Journal:  Br J Radiol       Date:  2016-12-12       Impact factor: 3.039

5.  Ultrasound-guided diagnostic breast biopsy methodology: retrospective comparison of the 8-gauge vacuum-assisted biopsy approach versus the spring-loaded 14-gauge core biopsy approach.

Authors:  Stephen P Povoski; Rafael E Jimenez; Wenle P Wang
Journal:  World J Surg Oncol       Date:  2011-08-11       Impact factor: 2.754

6.  Use of Core Needle Biopsy rather than Fine-Needle Aspiration Cytology in the Diagnostic Approach of Breast Cancer.

Authors:  Paola Pagni; Flaminia Spunticchia; Simona Barberi; Giuliana Caprio; Carlo Paglicci
Journal:  Case Rep Oncol       Date:  2014-07-11

7.  Vacuum-Assisted Excision, Scarless Solution for Fibroadenoma Breast-A Single-Center Experience.

Authors:  R Rupa; Suchana Kushvaha
Journal:  Indian J Radiol Imaging       Date:  2021-11-01

8.  Stereotactic large-core needle breast biopsy: analysis of pain and discomfort related to the biopsy procedure.

Authors:  Judith M Hemmer; Johannes C Kelder; Hans P M van Heesewijk
Journal:  Eur Radiol       Date:  2007-10-02       Impact factor: 5.315

9.  A comprehensive evaluation of the 8-gauge vacuum-assisted Mammotome(R) system for ultrasound-guided diagnostic biopsy and selective excision of breast lesions.

Authors:  Stephen P Povoski; Rafael E Jimenez
Journal:  World J Surg Oncol       Date:  2007-07-30       Impact factor: 2.754

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.